Influence of UV‐irradiation intensity and exposure duration on the hemobiocompatibility enhancement of a novel synthesized phosphobetaine zwitterions polyethersulfone clinical hemodialysis membranes
Notice bibliographique
Résumé
To improve the biocompatibility of polyethersulfone (PES) membranes utilized for biomedical hemodialysis (HD) applications, surface grafting with hydrophilic polymers has become a reliable modification strategy. Like most photochemical catalyzed reactions, UV-assisted grafting is distinctly advantageous for inducing permanent surface chemistry, enhancing hydrophilicity, improving morphology, and surface charge of membranes. PES membranes may be hydrophilic and chemically stable; however, they also have low protein-binding capacity and very susceptible to fouling and target analyte binding. In this study, novel zwitterionic polymers (PVP-ZW) have been synthesized by UV-assisted grafting PVP to a phosphobetaine monomer in a reaction involving dimethylamino and dioxaphospholane-2-oxide terminal groups in an NVP monomer solution at varying UV exposure conditions. The highlight of the present study is the investigation of the hemocompatibility of coated PES HD membranes at varying UV exposure conditions with respect to membrane chemistry and morphology and its influence on human serum protein adsorption. A clinical investigation of inflammatory biomarker release from incubated coated membranes within uremic blood samples of HD patients reveals they are weak complement and coagulation activators compared to bare PES membrane. The trend of fibrinogen adsorption on coated PES membranes was observed to increase with reducing UV intensity and exposure duration. Fibrinogen adhesion only increased with roughened membrane surfaces, and this also led to the formation of biological activation pathways hindering biocompatibility. Resistance against fibrinogen absorption on zwitterionic modified PES membrane could be linked with the creation of electrostatically induced neutral zwitterionic PVP-phosphobetaine hydration layer with hydrophilic character. Experimental results are accompanied by spectroscopic and morphological imaging evidence. Zwitterion coated PES membranes (PES-PVP-ZW) fabricated from higher UV intensities through longer exposure durations showed significant presence of surface deformations in the forms of inherent exfoliations due to harsh UV reaction conditions. The zeta potential and surface roughness of coated membranes also played significant role in the fibrinogen adsorption on PES membranes during ultrafiltration.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,014 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,002 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».