MétaCan
Menu
Back to cohort
Record W3200958365 · doi:10.1002/jbm.b.34936

Influence of UV‐irradiation intensity and exposure duration on the hemobiocompatibility enhancement of a novel synthesized phosphobetaine zwitterions polyethersulfone clinical hemodialysis membranes

2021· article· en· W3200958365 on OpenAlexaff
Ubong Eduok, Heloisa W.D. Camara, Amira Abdelrasoul, Ahmed Shoker

Bibliographic record

VenueJournal of Biomedical Materials Research Part B Applied Biomaterials · 2021
Typearticle
Languageen
FieldMaterials Science
TopicPolymer Surface Interaction Studies
Canadian institutionsSt. Paul's HospitalUniversity of Saskatchewan
Fundersnot available
KeywordsMembraneBiocompatibilityProtein adsorptionMaterials scienceAdsorptionGraftingPolysulfoneMonomerPolymerSurface modificationChemical engineeringPolymer chemistryChemistryOrganic chemistryBiochemistry

Abstract

fetched live from OpenAlex

To improve the biocompatibility of polyethersulfone (PES) membranes utilized for biomedical hemodialysis (HD) applications, surface grafting with hydrophilic polymers has become a reliable modification strategy. Like most photochemical catalyzed reactions, UV-assisted grafting is distinctly advantageous for inducing permanent surface chemistry, enhancing hydrophilicity, improving morphology, and surface charge of membranes. PES membranes may be hydrophilic and chemically stable; however, they also have low protein-binding capacity and very susceptible to fouling and target analyte binding. In this study, novel zwitterionic polymers (PVP-ZW) have been synthesized by UV-assisted grafting PVP to a phosphobetaine monomer in a reaction involving dimethylamino and dioxaphospholane-2-oxide terminal groups in an NVP monomer solution at varying UV exposure conditions. The highlight of the present study is the investigation of the hemocompatibility of coated PES HD membranes at varying UV exposure conditions with respect to membrane chemistry and morphology and its influence on human serum protein adsorption. A clinical investigation of inflammatory biomarker release from incubated coated membranes within uremic blood samples of HD patients reveals they are weak complement and coagulation activators compared to bare PES membrane. The trend of fibrinogen adsorption on coated PES membranes was observed to increase with reducing UV intensity and exposure duration. Fibrinogen adhesion only increased with roughened membrane surfaces, and this also led to the formation of biological activation pathways hindering biocompatibility. Resistance against fibrinogen absorption on zwitterionic modified PES membrane could be linked with the creation of electrostatically induced neutral zwitterionic PVP-phosphobetaine hydration layer with hydrophilic character. Experimental results are accompanied by spectroscopic and morphological imaging evidence. Zwitterion coated PES membranes (PES-PVP-ZW) fabricated from higher UV intensities through longer exposure durations showed significant presence of surface deformations in the forms of inherent exfoliations due to harsh UV reaction conditions. The zeta potential and surface roughness of coated membranes also played significant role in the fibrinogen adsorption on PES membranes during ultrafiltration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0140.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.084
GPT teacher head0.375
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part B Applied BiomaterialsSame topicPolymer Surface Interaction StudiesFrench-language works237,207