Lightweight and Amplitude-Free Ultrasonic Imaging Using Single-Bit Digitization and Instantaneous Phase Coherence
Notice bibliographique
Résumé
In the field of ultrasonic nondestructive testing (NDT), the total focusing method (TFM) and its derivatives are now commercially available on portable devices and are getting more popular within the NDT community. However, its implementation requires the collection of a very large amount of data with the full matrix capture (FMC) as the worst case scenario. Analyzing all the data also requires significant processing power, and consequently, there is an interest in: 1) reducing the required storage capacity used by imaging algorithms, such as delay-and-sum (DAS) imaging and 2) allowing the transmission and postprocessing of inspection data remotely. In this study, a different implementation of the TFM algorithm is used based on the vector coherence factor (VCF) that is used as an image itself. This method, also generally known as phase coherence imaging, presents certain advantages, such as a better sensitivity to diffracting geometries, consistency of defect restitution among different views, and an amplitude-free behavior as only the instantaneous phase of the signal is considered. Some drawbacks of this method must also be mentioned, including the fact that it poorly reproduces planar reflectors and presents a lower signal-to-noise ratio (SNR) than amplitude-based methods. However, previous studies showed that it can be used as a reliable tool for crack-like defect sizing. Thus, a lightweight acquisition process is proposed through single-bit digitization of the signal, followed by a phase retrieval method based on the rising and falling edge locations, allowing to feed the phase coherence imaging algorithm. Simulated and experimental tests were first performed in this study on several side-drilled holes (SDHs) in a stainless steel block and then extended to an experimental study on angled notches in a 19.05-mm ( 3/4" )-thick steel sample plate through multiview imaging. Results obtained using the array performance indicator (API) and the contrast-to-noise ratio (CNR) as quantitative evaluation parameters showed that the proposed lightweight acquisition process, which relies on binary signals, allows a reduction of the data throughput of up to 47 times. This throughput reduction is achieved while still presenting very similar results to phase coherence imaging based on the instantaneous phase derived from the Hilbert transform of the full waveform. In an era of increasing wireless network speed and cloud computing, these results allow considering interesting perspectives for the reduction of inspection hardware costs and remote postprocessing.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,002 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».