MétaCan
Menu
Back to cohort
Record W4220847653 · doi:10.1109/tuffc.2022.3163621

Lightweight and Amplitude-Free Ultrasonic Imaging Using Single-Bit Digitization and Instantaneous Phase Coherence

2022· article· en· W4220847653 on OpenAlexfundno aff
Baptiste Gauthier, Guillaume Painchaud-April, Alain Le Duff, Pierre Bélanger

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2022
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAmplitudeDigitizationAcousticsCoherence (philosophical gambling strategy)Ultrasonic imagingUltrasonic sensorPhase (matter)OpticsElectronic engineeringComputer sciencePhysicsEngineeringTelecommunications

Abstract

fetched live from OpenAlex

In the field of ultrasonic nondestructive testing (NDT), the total focusing method (TFM) and its derivatives are now commercially available on portable devices and are getting more popular within the NDT community. However, its implementation requires the collection of a very large amount of data with the full matrix capture (FMC) as the worst case scenario. Analyzing all the data also requires significant processing power, and consequently, there is an interest in: 1) reducing the required storage capacity used by imaging algorithms, such as delay-and-sum (DAS) imaging and 2) allowing the transmission and postprocessing of inspection data remotely. In this study, a different implementation of the TFM algorithm is used based on the vector coherence factor (VCF) that is used as an image itself. This method, also generally known as phase coherence imaging, presents certain advantages, such as a better sensitivity to diffracting geometries, consistency of defect restitution among different views, and an amplitude-free behavior as only the instantaneous phase of the signal is considered. Some drawbacks of this method must also be mentioned, including the fact that it poorly reproduces planar reflectors and presents a lower signal-to-noise ratio (SNR) than amplitude-based methods. However, previous studies showed that it can be used as a reliable tool for crack-like defect sizing. Thus, a lightweight acquisition process is proposed through single-bit digitization of the signal, followed by a phase retrieval method based on the rising and falling edge locations, allowing to feed the phase coherence imaging algorithm. Simulated and experimental tests were first performed in this study on several side-drilled holes (SDHs) in a stainless steel block and then extended to an experimental study on angled notches in a 19.05-mm ( 3/4" )-thick steel sample plate through multiview imaging. Results obtained using the array performance indicator (API) and the contrast-to-noise ratio (CNR) as quantitative evaluation parameters showed that the proposed lightweight acquisition process, which relies on binary signals, allows a reduction of the data throughput of up to 47 times. This throughput reduction is achieved while still presenting very similar results to phase coherence imaging based on the instantaneous phase derived from the Hilbert transform of the full waveform. In an era of increasing wireless network speed and cloud computing, these results allow considering interesting perspectives for the reduction of inspection hardware costs and remote postprocessing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.916
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.208
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207