MétaCan
← tous les travaux

WITHDRAWN: A method to isolate forces and moments applied to teeth: An in vitro experiment

2022· article· en· 0 citations· W4225297431 sur OpenAlex· 10.1016/j.ajodo.2022.03.010

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Organisme subventionnaire canadienUn organisme canadien l'a financé. Le travail peut ne porter aucune affiliation canadienne.

Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Dossier post-publication

Nature
Retraction
Motif
Concerns/Issues about Authorship/Affiliation;Date of Article and/or Notice Unknown;Removed;
Date
4/28/2022 0:00
Signalé par OpenAlex ?
Oui

Source : Retraction Watch, jointe par DOI. OpenAlex consigne la rétractation dans is_retracted, un booléen sur un espace d'états à au moins quatre valeurs ; il ne peut donc exprimer ni une expression de préoccupation, ni une correction, ni un rétablissement, et les rapporte comme false, ce qui se lit comme « rien à signaler ».

Scores machine (provisoires)

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Tête enseignante Opus0,015
Tête enseignante GPT0,316
Écart entre enseignants
0,301 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validation
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Résumé

•The Independent Mover (IM) system is a custom-made NiTi appliance designed with FEA.•The IM system reduced reactive forces and moments to subclinical values per tooth, in vitro.•With the IM system, the anchorage for every tooth movement is the rest of the dentition.•The IM system applies lighter forces and moments compared with 0.016'' NiTi lingual wire.•The IM system moves the teeth clinically independent. IntroductionWhen forces and moments are applied to teeth using traditional braces, an equal and opposite reaction is generated in teeth close to the subject tooth. This reaction diminishes as distance increases along the arch. Using a computational method called force moment enhancement, a new nickel-titanium orthodontic appliance has been designed to distribute these reactive forces across the entire arch. In this in vitro experiment, the Orthodontic SIMulator was employed to compare the reactive forces and moments of this newly designed orthodontic appliance, the independent mover (IM) system, with forces and moments generated by an 0.016-in nickel-titanium lingual mushroom-shaped archwire across the entire arch.MethodsAfter connecting each appliance passively to the orthodontic simulator in a temperature-controlled chamber set at 37°C, 5 trials with the lingual mushroom archwire and 10 trials with the IM system were conducted. Each trial consisted of movement of 1 of 3 teeth: 2-mm extrusion of a maxillary right second premolar, 2-mm intrusion of a maxillary left second premolar, and 1.5-mm buccal movement of a maxillary right lateral incisor. The forces and moments of every tooth were then recorded in the incisogingival, mesiodistal, and buccolingual dimensions, along with the corresponding rotational movements. They were then compared using a 2-sided t test.ResultsThe IM system generated significantly lower forces and moments at the moving teeth than the lingual mushroom archwire (P <0.001). The IM system distributed the reactive forces and moments to the rest of the dentition in a unison manner, breaking them down to subclinical values, a pattern that was fundamentally different from what was recorded for the lingual mushroom archwire in which the teeth next to the moving teeth felt heavy forces and moments (P <0.001).ConclusionsThe novel appliance can distribute the reactive forces and moments across the entire dental arch as if the anchorage for every tooth’s movement is the rest of the dentition. This design can allow the teeth to move clinically independent.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
American Journal of Orthodontics and Dentofacial Orthopedics
Thématique
Orthodontics and Dentofacial Orthopedics
Domaine
Dentistry
Établissements canadiens
Organismes subventionnaires
University of Alberta
Mots-clés
PremolarOrthodonticsMaxillary central incisorDentistryDental archArchBracketMaterials scienceMedicineEngineeringStructural engineeringMolar
Résumé présent dans OpenAlex
oui