Endometrial resection / ablation techniques for heavy menstrual bleeding
Notice bibliographique
Résumé
BACKGROUND: Heavy menstrual bleeding (HMB) is a significant health problem in premenopausal women; it can reduce their quality of life and cause anaemia. First-line therapy has traditionally been medical therapy but this is frequently ineffective. On the other hand, hysterectomy is obviously 100% effective in stopping bleeding but is more costly and can cause severe complications. Endometrial ablation is less invasive and preserves the uterus, although long-term studies have found that the costs of ablative surgery approach the cost of hysterectomy due to the requirement for repeat procedures. A large number of techniques have been developed to 'ablate' (remove) the lining of the endometrium. The gold standard techniques (laser, transcervical resection of the endometrium and rollerball) require visualisation of the uterus with a hysteroscope and, although safe, require skilled surgeons. A number of newer techniques have recently been developed, most of which are less time consuming. However, hysteroscopy may still be required as part of the ablative techniques and some of them must be considered to be still under development, requiring refinement and investigation. OBJECTIVES: To compare the efficacy, safety and acceptability of methods used to destroy the endometrium to reduce HMB in premenopausal women. SEARCH STRATEGY: We searched MEDLINE, EMBASE, CINAHL, PsycInfo, the Cochrane Central Register of Controlled Trials and the Cochrane Menstrual Disorders and Subfertility Group Specialised Register of controlled trials (from inception to August 2009). We also searched trial registers and other sources of unpublished or grey literature, reference lists of retrieved studies, experts in the field and made contact with pharmaceutical companies that manufactured ablation devices. SELECTION CRITERIA: Randomised controlled trials comparing different endometrial ablation techniques in women with a complaint of heavy menstrual bleeding without uterine pathology. The outcomes included reduction of heavy menstrual bleeding, improvement in quality of life, operative outcomes, satisfaction with the outcome, complications and need for further surgery or hysterectomy. DATA COLLECTION AND ANALYSIS: The two review authors independently selected trials for inclusion, assessed trials for quality and extracted data. Attempts were made to contact authors for clarification of data in some trials. Adverse events were only assessed if they were separately measured in the included trials. MAIN RESULTS: In the comparison of the newer 'blind' techniques (second generation) with the gold standard hysteroscopic ablative techniques (first generation), there was no evidence of overall differences in the improvement in HMB or patient satisfaction.Surgery was an average of 15 minutes shorter (weighted mean difference (WMD) 14.9, 95% CI 10.1 to 19.7), local anaesthesia was more likely to be employed (odds ratio (OR) 6.4, 95% CI 3.0 to 13.7) and equipment failure was more likely (OR 4.6, 95% CI 1.5 to 14.0) with second-generation ablation. Women undergoing newer ablative procedures were less likely to have fluid overload, uterine perforation, cervical lacerations and hematometra than women undergoing the more traditional type of ablation and resection techniques (OR 0.17, 95% CI 0.04 to 0.77; OR 0.32, 95% CI 0.1 to 1.0; OR 0.22, 95% CI 0.08 to 0.6 and OR 0.31, 95% CI 0.11 to 0.85, respectively). However, women were more likely to have nausea and vomiting and uterine cramping (OR 2.4, 95% CI 1.6 to 3.9 and OR 1.8, 95% CI 1.1 to 2.8, respectively). AUTHORS' CONCLUSIONS: Endometrial ablation techniques offer a less invasive surgical alternative to hysterectomy. The rapid development of a number of new methods of endometrial destruction has made systematic comparisons between methods and with the 'gold standard' first generation techniques difficult. Most of the newer techniques are technically easier than hysteroscopy-based methods to perform but technical difficulties with new equipment need to be ironed out. Overall, the existing evidence suggests that success rates and complication profiles of newer techniques of ablation compare favourably with hysteroscopic techniques.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,020 | 0,025 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,009 | 0,001 |
| Bibliométrie | 0,002 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».