MétaCan
Menu
Back to cohort

Endometrial resection / ablation techniques for heavy menstrual bleeding

2009· reference-entry· en· W4229719752 on OpenAlexaff
Anne Lethaby, Martha Hickey, Ray Garry, Josien Penninx

Bibliographic record

VenueCochrane Database of Systematic Reviews · 2009
Typereference-entry
Languageen
Field
Topic
Canadian institutionsRoyal Ottawa Mental Health Centre
Fundersnot available
KeywordsMedicineEndometrial ablationHysterectomyCINAHLMenstrual bleedingEndometriumMEDLINEElectrosurgeryHysteroscopySurgeryObstetrics

Abstract

fetched live from OpenAlex

BACKGROUND: Heavy menstrual bleeding (HMB) is a significant health problem in premenopausal women; it can reduce their quality of life and cause anaemia. First-line therapy has traditionally been medical therapy but this is frequently ineffective. On the other hand, hysterectomy is obviously 100% effective in stopping bleeding but is more costly and can cause severe complications. Endometrial ablation is less invasive and preserves the uterus, although long-term studies have found that the costs of ablative surgery approach the cost of hysterectomy due to the requirement for repeat procedures. A large number of techniques have been developed to 'ablate' (remove) the lining of the endometrium. The gold standard techniques (laser, transcervical resection of the endometrium and rollerball) require visualisation of the uterus with a hysteroscope and, although safe, require skilled surgeons. A number of newer techniques have recently been developed, most of which are less time consuming. However, hysteroscopy may still be required as part of the ablative techniques and some of them must be considered to be still under development, requiring refinement and investigation. OBJECTIVES: To compare the efficacy, safety and acceptability of methods used to destroy the endometrium to reduce HMB in premenopausal women. SEARCH STRATEGY: We searched MEDLINE, EMBASE, CINAHL, PsycInfo, the Cochrane Central Register of Controlled Trials and the Cochrane Menstrual Disorders and Subfertility Group Specialised Register of controlled trials (from inception to August 2009). We also searched trial registers and other sources of unpublished or grey literature, reference lists of retrieved studies, experts in the field and made contact with pharmaceutical companies that manufactured ablation devices. SELECTION CRITERIA: Randomised controlled trials comparing different endometrial ablation techniques in women with a complaint of heavy menstrual bleeding without uterine pathology. The outcomes included reduction of heavy menstrual bleeding, improvement in quality of life, operative outcomes, satisfaction with the outcome, complications and need for further surgery or hysterectomy. DATA COLLECTION AND ANALYSIS: The two review authors independently selected trials for inclusion, assessed trials for quality and extracted data. Attempts were made to contact authors for clarification of data in some trials. Adverse events were only assessed if they were separately measured in the included trials. MAIN RESULTS: In the comparison of the newer 'blind' techniques (second generation) with the gold standard hysteroscopic ablative techniques (first generation), there was no evidence of overall differences in the improvement in HMB or patient satisfaction.Surgery was an average of 15 minutes shorter (weighted mean difference (WMD) 14.9, 95% CI 10.1 to 19.7), local anaesthesia was more likely to be employed (odds ratio (OR) 6.4, 95% CI 3.0 to 13.7) and equipment failure was more likely (OR 4.6, 95% CI 1.5 to 14.0) with second-generation ablation. Women undergoing newer ablative procedures were less likely to have fluid overload, uterine perforation, cervical lacerations and hematometra than women undergoing the more traditional type of ablation and resection techniques (OR 0.17, 95% CI 0.04 to 0.77; OR 0.32, 95% CI 0.1 to 1.0; OR 0.22, 95% CI 0.08 to 0.6 and OR 0.31, 95% CI 0.11 to 0.85, respectively). However, women were more likely to have nausea and vomiting and uterine cramping (OR 2.4, 95% CI 1.6 to 3.9 and OR 1.8, 95% CI 1.1 to 2.8, respectively). AUTHORS' CONCLUSIONS: Endometrial ablation techniques offer a less invasive surgical alternative to hysterectomy. The rapid development of a number of new methods of endometrial destruction has made systematic comparisons between methods and with the 'gold standard' first generation techniques difficult. Most of the newer techniques are technically easier than hysteroscopy-based methods to perform but technical difficulties with new equipment need to be ironed out. Overall, the existing evidence suggests that success rates and complication profiles of newer techniques of ablation compare favourably with hysteroscopic techniques.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.020
metaresearch head score (Gemma)0.025
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow)
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.212
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0200.025
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0090.001
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.131
GPT teacher head0.386
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations97
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueCochrane Database of Systematic ReviewsFrench-language works237,207