Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients. Insights from a multicenter registry
Notice bibliographique
Résumé
Abstract Funding Acknowledgements Type of funding sources: None. Introduction A subset of more than 35,000 S-ICD is under FDA advisory, warning of the potential of premature battery depletion (PBD), caused by a faulty low-voltage capacitor. Based on internal data, the manufacturer projects the incidence at 3.7% after 5 years. Data independent from the manufacturer is sparse. Methods This study was a multicenter effort of 14 centers in Europe, the US, and Canada. Consecutive patients who received a S-ICD at the participating centers were included in this retrospective analysis. Patients with the 1010 S-ICD generator model, and those without available follow-up information were excluded. Data was collected and managed using REDCap electronic data capture tools hosted at the University Hospital Cologne. The primary endpoint in this registry was device explantation, generator replacement, or generator failure. Reasons for explantation, replacement, or failure were collected. Device longevity was defined in months. It was calculated as the time from device insertion to the time of replacement, or explantation, or failure, where applicable. Premature battery depletion was defined as the occurrence of battery depletion requiring generator replacement after 60 months or less. The study complies with the Declaration of Helsinki. Ethics committee approval was obtained. This study is registered with Clinicaltrials.gov. Results Data of n=1,102 S-ICD devices was analyzed. The registry comprised of S-ICD generators implanted between 03/2015 and 09/2021 (43.4% A209 model and 56.6% A219 model). Of these, 611 devices (55.4%) were identified by the Boston Scientific serial number lookup tool as affected by the advisory. The mean and median follow-up duration was 2.43±1.66 and 2.29 years, respectively. During follow-up, 110 devices (10%) were explanted after 2.9±1.7 years. Battery depletion was the indication in 52. The endpoint of PBD (battery depletion after less than 5 years) was met in 37 devices (6% of the devices under advisory), after 4.1±0.6 years. In 58 cases, the S-ICD was explanted for reasons other than battery depletion. Infection (16), system upgrade (20), heart transplant or LVAD therapy (7), and inappropriate shocks or inappropriate sensing (7) were the most common indications. Discussion This registry provides a systematic and manufacturer independent analysis of premature battery depletion in S-ICD patients. In the affected devices, the incidence of premature battery occurred in 6%. This is higher than what is projected by the manufacturer. The rate of PBD increases notably around the 4-year mark. Conclusion S-ICD generators under advisory suffer from PBD at a higher incidence than previously reported. Patients equipped with these devices should be closely monitored.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».