Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients. Insights from a multicenter registry
Bibliographic record
Abstract
Abstract Funding Acknowledgements Type of funding sources: None. Introduction A subset of more than 35,000 S-ICD is under FDA advisory, warning of the potential of premature battery depletion (PBD), caused by a faulty low-voltage capacitor. Based on internal data, the manufacturer projects the incidence at 3.7% after 5 years. Data independent from the manufacturer is sparse. Methods This study was a multicenter effort of 14 centers in Europe, the US, and Canada. Consecutive patients who received a S-ICD at the participating centers were included in this retrospective analysis. Patients with the 1010 S-ICD generator model, and those without available follow-up information were excluded. Data was collected and managed using REDCap electronic data capture tools hosted at the University Hospital Cologne. The primary endpoint in this registry was device explantation, generator replacement, or generator failure. Reasons for explantation, replacement, or failure were collected. Device longevity was defined in months. It was calculated as the time from device insertion to the time of replacement, or explantation, or failure, where applicable. Premature battery depletion was defined as the occurrence of battery depletion requiring generator replacement after 60 months or less. The study complies with the Declaration of Helsinki. Ethics committee approval was obtained. This study is registered with Clinicaltrials.gov. Results Data of n=1,102 S-ICD devices was analyzed. The registry comprised of S-ICD generators implanted between 03/2015 and 09/2021 (43.4% A209 model and 56.6% A219 model). Of these, 611 devices (55.4%) were identified by the Boston Scientific serial number lookup tool as affected by the advisory. The mean and median follow-up duration was 2.43±1.66 and 2.29 years, respectively. During follow-up, 110 devices (10%) were explanted after 2.9±1.7 years. Battery depletion was the indication in 52. The endpoint of PBD (battery depletion after less than 5 years) was met in 37 devices (6% of the devices under advisory), after 4.1±0.6 years. In 58 cases, the S-ICD was explanted for reasons other than battery depletion. Infection (16), system upgrade (20), heart transplant or LVAD therapy (7), and inappropriate shocks or inappropriate sensing (7) were the most common indications. Discussion This registry provides a systematic and manufacturer independent analysis of premature battery depletion in S-ICD patients. In the affected devices, the incidence of premature battery occurred in 6%. This is higher than what is projected by the manufacturer. The rate of PBD increases notably around the 4-year mark. Conclusion S-ICD generators under advisory suffer from PBD at a higher incidence than previously reported. Patients equipped with these devices should be closely monitored.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.014 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.003 | 0.004 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".