An Implantable Optogenetic Neuro-Stimulator SoC With Extended Optical Pulse-Width Enabled by Supply-Variation-Immune Cycled Light-Toggling Stimulation
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
The design, development, and experimental validation of an inductively-powered four-channel optical neuro-stimulator system on a chip (SoC) with on-chip neural recording, temperature monitoring, signal processing, and bidirectional wireless data communication are presented. A biologically-inspired optical stimulation approach is employed that extends the limitations on the stimulation pulse-width and frequency (i.e., enabling wirelessly-powered optical stimulation at very low frequencies (e.g., <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$< $</tex-math></inline-formula> 10 Hz)) while significantly reducing the required on-device storage capacitor size. The biological efficacy of the proposed approach is validated and compared with conventional stimulation through in vitro experiments. The stimulator's energy efficiency is enhanced by employing a high-gain (850 A/A) current amplifier/driver in each channel that steers up to 10 mA into the optical source with an excellent linearity ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$|INL|< $</tex-math></inline-formula> 0.5LSB), while 1) yielding the lowest-in-literature required voltage headroom, and 2) being insensitive to large (up to 12%) supply voltage drops, which is ideal for battery-less implantable devices. Additionally, to maximize the percentage of the generated optical power that reaches the targeted cells (thus, further energy efficiency enhancement), inkjet printing is utilized to fabricate custom-designed optical <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula> lenses that are placed directly on top of the silicon SoC to enhance the generated light's directivity by > <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$30\times$</tex-math></inline-formula> . An electrophysiological recording channel for real-time monitoring of the stimulation efficacy and a high-precision (0.1 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula> C resolution) temperature readout circuit for shutting off stimulation upon detection of an unsafe temperature increase are also integrated on the chip. Additionally, the SoC hosts an ASK receiver and an LSK transmitter for downlink and uplink wireless data communication, respectively. The SoC is fabricated in a standard 130 nm CMOS process and occupies 6 mm <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{2}$</tex-math></inline-formula> . Measurement results for different sensory and communication blocks are presented, as well as in vitro experimental validation results showing simultaneous optical stimulation, electrical recording, and calcium imaging.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle