A275 MECHANOSENSITIVE KCA2 + 1.1 CHANNEL MEDIATES INTRALUMINAL DISTENSION-INDUCED CALCIUM INFLUX IN ENTERIC NEURONS
Notice bibliographique
Résumé
Abstract Background The enteric nervous system (ENS) is the extensive neural network within the wall of the gastrointestinal (GI) tract that is essential for the control of gut function. However, the mechanisms whereby the ENS responds to the mechanical forces associated with distension are not well understood, and this has implications for gut function in health and disease. Purpose This study aims to determine the mechanisms underlying the responsiveness of enteric neural circuits in the myenteric plexus to intraluminal distension. Method Intact segments of the colon from mice expressing a genetically encoded fluorescent calcium reporter specifically in enteric neurons (Wnt-1-GCaMP6 mice) or cholinergic neurons (Chat-GCaMP6 mice) were bathed and luminally perfused with Krebs solution in a custom-designed chamber (35-37°C, 95% O2 ,5% CO2, pH 7.4). Intracellular Ca2+ fluorescence in enteric neurons was visualized by live-cell confocal microscopy and was analyzed using Imaris™ software. Intraluminal distension was accomplished either by increasing luminal perfusion pressure or using colonic preparations containing natural fecal pellets. The degree of intraluminal distension produced by perfusion was defined by the relative distance between identified neurons in preparation and is expressed as a percentage increase in the distance between them. Distension was studied over a range from 0-75%. The degree of distension produced by a fecal pellet in the distal colon is approximately 75%. Result(s) Intraluminal distension significantly increased intracellular Ca2+ fluorescence in most (>85%) of neurons of the myenteric plexus. When the colon was distended, the response to depolarization by KCl, a general cell depolarization activator, and DMPP, a nicotinic receptor agonist in Wnt1-cre GCaMP6 mice and Chat GCaMP6 mice, respectively was substantially inhibited. To identify how distention induced an increase in intracellular Ca2+ fluorescence and inhibited depolarization, pharmacological inhibitors of mechanosensitive ion channels were used. The nonspecific mechanosensitive channel inhibitor, gadolinium (50 mM) and the Kca1.1 channel inhibitor, paxilline (10 mM), both significantly reduced the luminal distension-induced increase in intracellular Ca2+ fluorescence. The effect of luminal distension-inhibited cell depolarization by KCl recovered in the presence of paxilline. This was not observed in the Ca2+ responses evoked by DMPP, suggesting that other mechanisms may play a role in the inhibition of neuronal responses in cholinergic enteric neurons. Conclusion(s) The majority of neurons of the colonic myenteric plexus are mechanosensitive and show an increase in intracellular Ca2+ when the gut is distended. Myenteric neurons do not respond to nicotinic receptor activation when the gut is distended through a mechanism that is dependent on the activity of Kca1.1 channel. Supported by CIHR Disclosure of Interest None Declared
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».