Investigation of the Dosimetry Characteristics of the GAFCHROMIC® EBT3 Film Response to Alpha Particle Irradiation
Notice bibliographique
Résumé
Abstract The purpose of this study was to investigate the dosimetric characteristics of the GAFCHROMIC® EBT3 film responding to alpha particle irradiation. Unlaminated GAFCHROMIC® EBT3 film pieces, were irradiated with a 30.055 kBq 241 Am alpha source, at eight different dose levels, between 0 and 509 Gy. The irradiations were performed inside an enclosed box. Epson Expression 10000 XL scanner in transmission mode was used to digitize irradiated films 24 hours post-irradiations as 16-bit RGB images in tagged image file format (TIFF). Optical density (OD) values were obtained by following the OD theorem. Raw and normalized pixel values (PV norm ) from the red, green, and blue colour channels were sampled from a 3 × 3 mm 2 region of interest. Calibration curves were created for both data sets (OD and PV norm ) and were fit accordingly. Monte Carlo simulations with the Geant4 toolkit were performed to establish a dose rate at the point within the sensitive layer of the film. An alpha dosimetry protocol for EBT3 films was obtained from the Monte Carlo calculated dose rate and dose calibration curves for alpha radiation were created. It is necessary to extend this study for different film types and compare to photon dosimetry calibration curves.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».