A new instrument for interfacial dilational rheology
Notice bibliographique
Résumé
We present a new design for an interfacial dilational rheometer that can generate oscillatory dilational strain on a planar air-liquid interface. The strain is generated by a pneumatic mechanism involving a deformable film, which forms a circular barrier that can contract or expand under different pressures. The interfacial stress is measured using a Wilhelmy rod. We carefully examine and demonstrate the effects of potential sources of measurement error, including inertia, drag, buoyancy, flow from the bulk phase, and surface waves. The design avoids mixed deformations present in other instruments and is currently capable of accurate measurements at frequencies up to ∼0.1 Hz and dilational strains below 0.001, with potential for higher frequencies after further theoretical development. We demonstrate the integration of the interfacial dilational rheometer with a Langmuir trough by measuring the compression isotherm of an insoluble surfactant, stearic acid. Furthermore, we verify the capability of the interfacial dilational rheometer to perform frequency and amplitude sweeps and present the storage and loss moduli for a water-soluble surfactant, sodium dodecylbenzenesulfonate, at different concentrations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».