P567 Impact of recent thiopurine use on ozanimod safety in patients with ulcerative colitis: a post hoc analysis of the phase 3 True North study
Notice bibliographique
Résumé
Abstract Background Ozanimod, a sphingosine 1-phosphate (S1P) receptor modulator that selectively targets S1P1 and S1P5, is approved for the treatment of moderately to severely active ulcerative colitis (UC) in adults based on results from the phase 3 True North study (NCT02435992). Reductions in absolute lymphocyte count (ALC) are expected with ozanimod but not associated with treatment-emergent adverse events (TEAEs). This post hoc analysis explored the effect of recent use of thiopurines on ALC and safety outcomes in patients treated with ozanimod. Methods True North was a phase 3 trial of ozanimod induction and maintenance therapy in moderately to severely active UC. Patients in Cohort 1 were randomised to once-daily double-blind treatment with ozanimod 0.92 mg or placebo; patients in Cohort 2 received open-label ozanimod for a 10-week induction period. Patients on concomitant thiopurines were required to stop therapy at study start without a washout period. In this post hoc analysis, patients were stratified by recent prior thiopurine use (within 90 days of ozanimod initiation). ALC was assessed at baseline; ALC, TEAEs, and infectious outcomes were assessed during the induction period at Weeks 5 and 10. Results Of the 1012 patients in True North, 796 were treated with ozanimod and analysed (n=57 with recent thiopurine exposure; n=739 without recent thiopurine exposure). At baseline, mean ALC (×109/L [SD]) was slightly lower in patients with than without recent thiopurine use (Table). Both groups had similar baseline incidence of ALC <200 cells/µL (0%) and <500 cells/µL (range 0.0–0.3%). While ALC <200 cells/µL and <500 cells/µL were more prevalent among patients with than without recent thiopurine use (Figure), the reductions from baseline to Week 10 in ALC were similar in both groups (Table). Rates of infection were also similar in patients with recent thiopurine use (14.7% in Cohort 1 and 13.0% in Cohort 2) and without recent thiopurine use (10.4% and 12.5%, respectively). The most frequent infection was nasopharyngitis in both groups: 8.8% in Cohort 1 and 0% in Cohort 2 in patients with recent thiopurine use; 3.0% and 2.9%, respectively, in patients without recent thiopurine use. There were no serious adverse events (AEs) related to ozanimod treatment, and treatment discontinuations were similar in patients with and without recent thiopurine exposure. Conclusion Lower ALC was observed in patients starting ozanimod within 90 days of thiopurine use but was not associated with an increased incidence of infection or serious AEs. The findings suggest switching from thiopurines to ozanimod without a washout period may be safe and tolerable.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,007 | 0,006 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,004 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».