Impact of varying soil conditions on the design of tall building foundations
Notice bibliographique
Résumé
Above the past two decades, there has been a significant rise in the construction of tall structures over 150m in height, with an almost exponential development rate. Numerous similar structures have been built throughout the Middle East and Asia, and many more are proposed or now under development. Buildings over 300m in height are posing new engineering difficulties, especially in terms of structural and geotechnical design. Wind analysis is critical when it comes to big structures. Geotechnical engineers, in particular, are progressively abandoning empirical techniques in favor of state-of-the-art methods when designing foundations for super-tall structures. Numerous studies have investigated the structural behavior of tall structures with SSI by taking into account a variety of factors such as foundation type, soil conditions, lateral stresses, and the ratio of the flexural stiffness of the beam and column. Very few studies on the soil-structure interaction of tall structures in clayey soil conditions, especially in Indian seismic zones, have been conducted. In zone III, a G+18-story rectangular structure with a 3 m floor-to-floor height was assessed using the E-tabs software. The selected plan is rectangular in shape. The structure has been evaluated for static and dynamic wind and seismic forces. Structures have been developed for use in circumstances of hard, medium, and soft soil.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».