B-224 Rapid, Extraction-Free, and Portable Molecular Detection of HIV-1 and HCV Directly From Whole Blood
Notice bibliographique
Résumé
Abstract Background Early diagnosis of human immunodeficiency virus-1 (HIV-1) and hepatitis C virus (HCV) is key to preventing viral transmission and improving linkage to treatment. Isothermal amplification methods, such as reverse transcription looped-mediated amplification (RT-LAMP), have enabled molecular diagnostics to expand beyond centralized laboratories. Despite the advances in molecular point-of-care (POC) testing, many of these tests are costly and still depend on a reliable power-source, specialized equipment, and cold-chain storage, making them impractical for resource-limited settings. To overcome these barriers, there is a need for innovative molecular diagnostics for blood-borne pathogens. Here, we propose a simple, extraction-free, portable workflow for detecting HIV-1 and HCV from whole blood within 40 minutes. Methods We developed singleplex RT-LAMP-based tests using modified published primer sets. Contrived whole blood samples containing HIV-1 or HCV virions were diluted in equal parts water and loaded directly into optimized RT-LAMP master mixes. To mitigate cold-chain storage dependence, RT-LAMP reactions were performed using a lyophilized master mix. The reactions were heated for 30 minutes using a hand-held, battery-powered heating device for simultaneous virion lysis and amplification. For simple visual detection, amplification was coupled with a lateral flow-based dipstick test. The analytical sensitivity of each detection test was evaluated using contrived whole blood samples ranging in HIV-1 and HCV 1a viral loads. Additionally, HCV detection was evaluated on genotypes 1b, 2b, and 3a. For result confirmation, a custom CRISPR-Cas12a-based assay was used to verify the presence or absence of pathogen-specific amplicons following amplification. Results The diagnostic workflow can be completed within 40 minutes, including less than 10 minutes of hands-on time. At optimal conditions, the HIV-1 and HCV 1a singleplex tests had lower limits of detections of 4.89 log10 cp/mL and 3.77 log10 IU/mL, respectively. Evaluation of the published literature showed that these viral loads are within the ranges observed during acute HIV-1 and HCV infection. HCV detection was also observed for genotypes 1b and 3a, albeit at a lower sensitivity than genotype 1a. No detection was observed for genotype 2b, presumably due to the lower viral loads of the samples. No cross-reactivity between the two tests was observed. Conclusions Our proposed workflow allows for rapid detection of blood-borne pathogens without the need for complex equipment or cold-chain storage, showing potential for application in resource-limited settings. Additional validation within a clinical setting using fingerstick blood remains to be tested.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».