MétaCan
Menu
Retour à la cohorte
Enregistrement W4407239073 · doi:10.33137/cpoj.v7i2.44494

DEVELOPMENT AND EVALUATION OF AN ANTERIORLY MOUNTED MICROPROCESSOR-CONTROLLED POWERED HIP JOINT PROSTHESIS

2025· article· en· W4407239073 sur OpenAlexafffundvenueabout
Kelly Brannen, Natalie Baddour, Lucas Cho, David Langlois, Patrick Dumond, Edward D. Lemaire

Notice bibliographique

RevueCanadian Prosthetics & Orthotics Journal · 2025
Typearticle
Langueen
DomaineEngineering
ThématiqueProsthetics and Rehabilitation Robotics
Établissements canadiensOttawa HospitalUniversity of Ottawa
Organismes subventionnairesUniversity of Ottawa
Mots-clésProsthesisJoint (building)GaitComputer scienceAnkleBiomechanicsSimulationPhysical medicine and rehabilitationOrthodonticsMedicineEngineeringSurgeryStructural engineering

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Prosthetic solutions for individuals with hip disarticulation and hemipelvectomy amputations currently rely exclusively on passive hip joint mechanisms. Although powered knee and ankle joint prostheses have improved gait in people with amputation, no powered hip joint options are commercially available. OBJECTIVE: To develop and validate the mechanism, structural integrity, and design of an anteriorly mounted powered hip joint prosthesis. METHODOLOGY: A microprocessor-controlled powered hip joint prosthesis (PHP) was developed, incorporating a cable-and-pulley transmission system. Stress calculations and Finite Element Analysis (FEA) were performed to ensure that the device can withstand the forces from daily activities. The prototype underwent mechanical strength testing in accordance with International Organization for Standardization (ISO) 15032:2000 standards, ensuring suitability for user loads of up to 100 kg. For functional testing, three able-bodied individuals were video recorded while walking with the power hip in a prosthesis simulator. For each participant, hip angles and stride parameters during level walking were assessed by analyzing five gait cycles. FINDINGS: The novel PHP met most of the design criteria; however, it protruded 56 mm anteriorly from the lamination plate, exceeding the specified criterion of 20 mm. The joint's range of motion included 22° of extension and 145° of flexion. The joint prototype's height was 347 mm, and it weighed 3.9 kg. Furthermore, it passed ISO 15032:2000 strength tests, withstanding a 3360 Newton (N) load without failure. The device successfully enabled able-bodied individuals to walk using a hip disarticulation simulator and supported a 98 kg user during level walking. CONCLUSION: The microprocessor-controlled PHP exhibited successful performance in both mechanical strength and functional testing. Future work is needed to optimize and assess the design, which could reduce the device's weight and size. A complex control system to adjust gait based on pelvic motion is currently under development. Layman's Abstract Currently, prosthetic solutions for people with hip disarticulation and hemipelvectomy amputation rely solely on passive prosthetic hip joints. While powered knee and ankle joints prostheses can improve gait, there are no powered hip joints prostheses available on the market. This study introduced and evaluated a powered hip joint prosthesis with a cable-and-pulley transmission system. The powered hip joint prosthesis met most of the design criteria and has range of motion of 22° of extension and 145° of flexion. The heigh of the joint was 347 mm, and it weighed 3.9 kg. Furthermore, it passed the strength tests, withstanding a 3360 Newton (N) load without failure. To evaluate the joint's performance, testing was conducted with three able-bodied individuals using a prosthesis simulator during level walking. This joint successfully enabled able-bodied individuals to walk and supported a 98 kg user during level walking. Future work is needed to optimize and assess the design, to reduce the device's weight and size. Furthermore, a control system to improve movement and function is needed and is currently under development. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/44494/33657 How To Cite: Brannen K, Baddour N, Cho L, Langlois D, Dumond P, Lemaire E.D. Development and evaluation of an anteriorly mounted microprocessor-controlled powered hip joint prosthesis. Canadian Prosthetics & Orthotics Journal. 2024; Volume 7, Issue 2, No. 7. https://doi.org/10.33137/cpoj.v7i1.44494 Corresponding Author: Professor Edward Lemaire, PhDAffiliation: Department of Medicine, Faculty of Medicine, University of Ottawa, Ottawa, Canada.E-Mail: elemaire@uottawa.caORCID ID: https://orcid.org/0000-0003-4693-2623

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Simulation ou modélisation · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,660
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,013
Tête enseignante GPT0,248
Écart entre enseignants0,235 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeSimulation ou modélisation
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations2
Publié2025
Routes d'admission4
Résumé présentoui

Explorer davantage

Même revueCanadian Prosthetics & Orthotics JournalMême sujetProsthetics and Rehabilitation RoboticsTravaux en français237 207