Passive Control of Base Flow and Impact of Quarter Rib Radius and Locations at Sonic Mach Number
Notice bibliographique
Résumé
This study assesses the effectiveness of passive control as a quarter circle at Mach M = 1 for a duct of diameter 22 mm of length L = 1D to 6D. The study was conducted for a nozzle pressure ratio of 1.5 to 5. At sonic Mach M = 1, when the passive control is placed at various locations in the duct, the optimum location and radius of the rib seem to be 1D, 1.5D, 2D, and 4 mm, resulting in a base pressure almost double the ambient pressure for orientation1 of the rib where flow from the Nozzle sees curved part of the rib. The base pressure equals the ambient pressure for a 3 mm rib radius at 1D, 1.5D, and 2D. When the rib is located at 0.5D, there is an increase in the base pressure due to the presence of the rib. However, the base pressure magnitude is lower than attained for 1D, 1.5D, 2D, and 3D rib locations. The best options for orientation 2 of the rib locations are 1.5D and 2D. No appreciable results are obtained when the rib is placed at 3D for both orientations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».