Characterization and performance of the Apollon main short-pulse laser beam following its commissioning at 2 PW level
Notice bibliographique
Résumé
We present the results of the second commissioning phase of the short-focal-length area of the Apollon laser facility, located in Saclay, France. This phase was conducted using the main laser beam (F1), scaled to a peak power of 2 PW. Under the tested conditions, the F1 beam delivered on-target pulses with a maximum energy of up to 45 J and a duration of 22 fs. Several diagnostics were deployed to assess the facility's performance. Key measurements included the on-target focal spot and its spatial stability, along with characterizations of secondary sources generated by irradiating solid targets. These evaluations aim at assisting users in designing future experiments. The laser-target interactions were thoroughly characterized, with emissions of energetic ions, x rays, and neutrons recorded, demonstrating good laser-to-target coupling efficiency. Additionally, we successfully demonstrated the simultaneous operation of the F1 beam with the auxiliary 0.5 PW F2 beam of Apollon, enabling dual-beam operation. This commissioning phase paves the way for the next stage in 2025, which will involve scaling the F1 beam to 8 PW, progressing toward the ultimate goal of achieving 10 PW power.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».