Comparison of curing methods for bulk electrical conductivity testing of cement pastes
Notice bibliographique
Résumé
Abstract Predicting the service life of concrete is one of the main problems faced by civil engineers. Measuring its electrical conductivity is a promising method to quickly find a qualitative indication of the ionic diffusion behaviour of a cementitious mix and, therefore, of its durability. However, one limitation on the ability to quantitatively measure bulk conductivity is the effect of the curing method on the measurement. The main phenomenon that occurs during curing and affects the conductivity is the leaching of alkalis from the pore solution into the curing solution driven by the alkali concentration gradient between these two solutions. The pore solution is therefore depleted in alkalis, reducing both pore solution and bulk conductivity. However, previous work has shown that leaching is not the only effect that the curing solution can have on the bulk conductivity. To avoid these effects, the curing solution must simulate the pore solution at each moment of hydration and for each cementitious mix. For this purpose, different curing solutions based on a sacrificial powder, a reduced volume of curing solution, and a simulated pore solution are proposed and investigated experimentally. The results show that a small volume of curing solution is the most promising method to prevent leaching without affecting the hydration rate.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».