MétaCan
Menu
Retour à la cohorte
Enregistrement W4413141786 · doi:10.2196/82013

Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study

2025· preprint· en· W4413141786 sur OpenAlexvenueno aff
Fatemeh Keshavarzi, Mokhtar Arazpour, Saeed Behzadipour

Notice bibliographique

RevueJMIR Biomedical Engineering · 2025
Typepreprint
Langueen
DomaineMedicine
ThématiqueParkinson's Disease and Spinal Disorders
Établissements canadiensnon disponible
Organismes subventionnairesUniversity of Social Welfare and Rehabilitation Sciences
Mots-clésTrunkKyphosisIsometric exerciseWhole body vibrationLeaf springVibrationOrthodonticsDisplacement (psychology)MedicineSpring (device)Physical medicine and rehabilitationPhysical therapyStructural engineeringPhysicsEngineeringSurgeryAcousticsPsychology

Résumé

récupéré en direct d'OpenAlex

<sec> <title>BACKGROUND</title> Application of spinal orthoses and local vibration in the treatment of hyperkyphosis is a developing concept. Further research is needed to determine the impact of leaf springs and local vibration techniques on the neuromusculoskeletal system. </sec> <sec> <title>OBJECTIVE</title> To evaluate the effect of the simultaneous application of a leaf spring and a programmed local vibration system in a spinal orthosis on thoracic kyphosis angle and trunk flexor and extensor muscles' function. </sec> <sec> <title>METHODS</title> We used a soft thoracolumbar orthosis as a basis for a parallel leaf spring bar made by AISI 1075 steel with (45cm×2cm×2mm) dimensions. We added and evaluated two local vibration systems with predefined force, Probe displacement and programmed frequency. Each local vibration unit was positioned alongside the spinal column, at a distance of 12 cm, while wearing the orthosis. Then one person used the orthosis. We assessed thoracic kyphosis and trunk flexor/extensor muscle function (isometric, isotonic, and isokinetic) before and after a four-week intervention. </sec> <sec> <title>RESULTS</title> Results indicated that each vibration unit caused an on-body displacement of 3 to 6 mm and a free displacement of 1 cm, operating at 8 Hz with a force of 20 N, current of 300 mA, and voltage of 12 V over an area of 12.56 cm². Each session lasted 10 seconds with a 5-minute rest, totalling 12 repetitions. After 4 weeks, the thoracic kyphosis angle decreased from 47.24 to 45.81 degrees. In isometric tests, extensors improved strength by 22.2% to 50%, while flexors decreased torque by -24.1% to -26.5% but achieved faster force generation (-50% half-peak time). Isotonic concentric tests showed extensors improving power by 66.7% to 100% and efficiency, with flexors experiencing reduced power output (12.5-14.3%) but better control (40% decay time). In isotonic eccentric tests, flexors increased peak power by 44.4% and decreased average power (-16.7%), while extensors maintained baseline power but improved efficiency by 20%. Isokinetic tests revealed flexors improved peak torque by 233% and work capacity by 200%, while extensors increased by 66.7% with efficient torque development (55.2% time to peak). </sec> <sec> <title>CONCLUSIONS</title> This study demonstrated the feasibility of a semi-rigid thoracolumbar orthosis with integrated programmable vibration in the management of hyperkyphosis. This system achieved good user acceptance and a reduction in thoracic kyphosis. Extensor muscle performance and modified flexor activation patterns improved. Muscle-specific responses warrant targeted rehabilitation approaches, and the solenoid system delivers effective mechanical stimulation while maintaining comfort. These results support further development of combined biomechanical-neuromuscular orthotic interventions for spinal rehabilitation. </sec> <sec> <title>CLINICALTRIAL</title> This study was the first phase of the first author thesis project protocol that received approval from the ethics committee of the University of Social Welfare and Rehabilitation Sciences in January 2023. The approval code was (IR.USWR.REC.1401.217).This thesis project protocol received approval from the ethics committee of the University of Social Welfare and Rehabilitation Sciences, with an approval code (IR.USWR.REC.1401.217) in January 2023. The protocol for RCT of this thesis was subsequently approved by the Iranian Registry of Clinical Trials on February 14, 2023, with the registration reference code IRCT20190811044505N2. </sec>

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,344
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,011
Tête enseignante GPT0,284
Écart entre enseignants0,273 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJMIR Biomedical EngineeringMême sujetParkinson's Disease and Spinal DisordersTravaux en français237 207