How much K is OK? Evaluating different methods for K-concentration determination and the effect of the internal K concentration on feldspar luminescence dating
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Abstract. For luminescence dating of potassium-rich (K) feldspars, the presence of 40K within the K-feldspar grains contributes significantly to the internal dose rate of the sample. Whilst it is common practice to determine uranium, thorium,, and potassium concentrations for external dose rate calculations, the vast majority of studies do not measure the internal K concentration. Instead, most studies apply published K concentrations of 10 ± 2 % (Smedley et al., 2012), 12.5 ± 0.5 % (Huntley and Baril, 1997), or 13 ± 1 % (Zhao and Li, 2005) to their samples. The use of these high literature-based K concentrations is usually justified by two assumptions: (i) only K-feldspar grains with high K concentrations contribute to the luminescence signal significantly, and (ii) we reliably exclude Na-feldspar luminescence signals using filters, with a narrow transmission window around the K-feldspar emission peak of ∼ 410 nm. However, these assumptions may not apply to all samples, and assuming K concentrations that are too high might result in significant dose rate overestimation. To investigate the effect of the internal K concentration on the dose rate and the validity of the above-mentioned assumptions, we determine the K concentration of a set of 10 density-separated sand-sized K-feldspar samples of different geological origin and chemical composition using four different techniques. We quantify their K concentration on the bulk level using a wavelength-dispersive X-ray fluorescence spectrometer and a β counter and on the single-grain level using a micro X-ray fluorescence spectrometer and a scanning electron microscope (SEM) with an energy-dispersive spectroscopy (EDX) attachment. We use the SEM-EDX single-grain results to calculate two luminescence-weighted K estimates. These two estimates, effective K and luminescent grains, connect the K concentration of a grain to its luminescence signal intensity. Our experimental results show that (1) there is a good agreement between bulk and average single-grain K-concentration measurements, (2) single-grain K concentrations within one sample can be highly variable across the entire physically possible range of K concentrations for feldspars, and (3) the blue luminescence emission is not dominated by K-rich feldspar grains. For most samples there are considerable differences between the published and the measured K concentrations. These differences result in overestimation of the total dose rate of up to 34.6 % compared to dose rates calculated using measured K concentrations. We therefore suggest routinely measuring the bulk K concentration of each sample, complemented by additional single-grain K-concentration measurements.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle