<sup>68</sup> Ga-Labeled Peptides Targeting Oxytocin Receptor in Breast Cancer Using Linchpin Chemistry for Tandem Peptide Cyclization and Radiometal Chelator Incorporation
Notice bibliographique
Résumé
Breast cancer remains a leading cause of cancer-related death worldwide, partly due to disease heterogeneity and the lack of reliable biomarkers. The G protein-coupled oxytocin receptor (OTR) has emerged as a potential biomarker and therapeutic target in breast cancer, as its overexpression correlates with tumor growth and metastasis. OTR thus presents new opportunities for molecular imaging and targeted therapy in breast cancer. This study explores three novel 68 Ga-labeled peptides as potential OTR-specific imaging agents. Their preclinical evaluation includes in vitro assays and positron emission tomography (PET) studies in breast cancer models. The work also introduces the application of linchpin chemistry with LP1 and LP2 as a novel strategy for attaching bifunctional chelating agents. This tandem approach not only enables efficient peptide cyclization but also facilitates radiometal incorporation, representing a versatile platform for the design of next-generation radiopharmaceuticals. Binding studies using an aequorin-based assay in CHO cells expressing human OTR revealed the following EC 50 values: nat Ga-LP1-oxytocin (376 nM), nat Ga-DOTA-Lys 8 -oxytocin (1.38 nM), and nat Ga-LP2-oxytocin (123 nM). Radiolabeling with 68 Ga was efficient and reproducible, consistently yielding high decay-corrected radiochemical yields of 52–74% and high radiochemical purity >98%. PET imaging demonstrated maximum MCF-7 tumor uptake for 68 Ga-LP1-oxytocin (SUV max 0.64 ± 0.10; n = 3) and 68 Ga-LP2-oxytocin (SUV max 0.64 ± 0.05; n = 7) at 10 min postinjection, whereas 68 Ga-DOTA-Lys 8 -oxytocin reached comparable uptake (SUV max 0.64 ± 0.12; n = 3) at 30 min. Notably, 68 Ga-LP2-oxytocin showed superior background clearance and faster blood pool washout. Tumor uptake specificity was verified through competitive inhibition studies: predosing with oxytocin reduced tracer accumulation in a concentration-dependent manner at 10 min postinjection, with decreases of 33% at 50 μM and 68% at 300 μM, confirming selective OTR-mediated binding in vivo. Among the evaluated tracers, the novel 68 Ga-LP2-oxytocin peptide demonstrated efficient radiolabeling, strong binding potency, and favorable in vivo characteristics, including uptake in estrogen receptor-positive MCF-7 tumors and superior background and clearance profiles. With further structural optimization, 68 Ga-LP2-oxytocin holds promise as a PET radioligand for targeting OTR in breast cancer.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».