Practical experiments with ultra-low voltage biomedical amplifiers
Notice bibliographique
Résumé
Low power amplifiers are crucial in many biomedical devices such as muscle signal interfaces and neurological front ends. Furthermore, their importance in analog computing platforms is gaining ground as they provide improved efficiency under increasing demands. As such, reducing amplifier's operational voltage is imperative for low power design. Two topologies were optimized and tested for useful gain at low voltage. A first topology was tested in CMOS and with OTS components, it used body input transconductance. The second, a common source design using an array of MOSFETs that minimized the voltage stack whilst maximizing gain. Both methods provided suitable gain for application in biomedical circuits, and were tested using practical interface biasing. The body amplifier provides useful gain down to 290mV and the CS amplifier provides suitable gain down to 190mV.Clinical and Translational Impact Statement-Low voltage and low power amplifiers reduce risks, as battery longevity is extended. As such, they are a crucial component of medical devices and implants such as heart monitors, pacemakers and health tracking. In addition, these amplifiers are poised to gain importance in biomimetic computing systems based on analog memory.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».