Weaning to Extubation Directly from High-Frequency Oscillatory Ventilation in an Infant with Cystic Lung Disease and Persistent Air leak: A Strategy for Lung Protection
Notice bibliographique
Résumé
We report the successful weaning and extubation of an infant from a SensorMedics 3100A high-frequency oscillator without returning to conventional ventilation. A 7-week-old term infant with respiratory syncytial virus bronchiolitis complicated by cystic pulmonary lesions repeatedly failed attempts to return to conventional ventilation from high-frequency oscillatory ventilation (HFOV) for weaning, because of recurrent pneumothoraces. A computed tomography of the chest revealed multiple well defined cysts of various sizes involving both lungs. Therefore, weaning to extubation from HFOV was proposed as a way of preventing further air leak. The weaning strategy consisted of a technique we refer to as "sprinting." Using this method, the patient was successfully extubated directly from HFOV, with no complications. A follow-up computed tomography of the chest showed marked improvement in the size of the cystic lesions. The patient was discharged home with no need for home oxygen therapy.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».