Islanding protection of synchronous distributed generators using intelligent relays
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
The penetration of distributed generation (DG) in electrical distribution systems has been consistently increasing due to its great potential to improve system performance in terms of reliability, power quality and loss reduction. However, achieving these benefits is not trivial given the diverse issues resulting from distributed generation integration. One of them is the islanded operation of DGs since such operation generates hazards for human safety and compromises electrical network quality and infrastructure. It is thus current practice, according to DG Interconnection Guidelines to disconnect all DGs upon unintentional islanding detection. This thesis proposes the use of Intelligent Relay (IR) as a passive device for islanding detection of synchronous DGs and outlines the setting methodology. The intelligent relay employs multi-variate analysis and data mining techniques to extract the patterns of islanded synchronous DGs from time-domain features obtained from off-line simulation of typical islanding events. The captured islanding signature for any DG is represented in the form of a Decision Tree (DT) which determines the tripping logic, protection handles and thresholds of the Intelligent Relay.A distribution feeder with multiple DGs connected is modeled in Simulink as a benchmark system for Intelligent Relay testing. The performance of the IR is quantified in terms of Dependability and Security indices and is compared to the performance of conventional passive protective relays. In order to simulate realistic situations, a variety of operating conditions is configured and operating condition-dependent dedicated IR settings are obtained. The validity and applicability of the obtained IR settings are examined for an unknown set of islanding and non-islanding events including the ones originating from symmetrical, asymmetrical and arcing shunt faults. Last, but not least, a method is proposed to use the high-performance dedicated relay settings in an adaptive fashion in order to accommodate a range of similar operating conditions, thus avoiding repetitive IR training. The IR was found to exhibit consistently superior overall performance to all considered currently used passive protective devices. It also features a much smaller Non-Detection-Zone by virtue of its superior performance for islanding conditions where the load and the formed island generation are nearly balanced.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,002 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle