Packed red blood cells and stored whole blood transfusions in dogs. A retrospective study in 86 recipients transfused at a Canadian veterinary teaching hospital
Notice bibliographique
Résumé
Veterinary transfusion medicine is an essential part of therapy for critical patients in small animals. Many updates have been made in recent years and blood transfusion (either packed red blood cell, PRBC or stored whole blood, SWB) has been used to treat different disorders inducing canine anemia to improve oxygen delivery to the peripheral tissues (1,2,3). The aims of this study were to classify anemia in transfused-recipients and to analyze the hematocrit (Hct) value increase post-transfusion in relation to: pre-transfusion Hct, type of anemia (acute or chronic), type of product used (PRBC or SWB), donor’s Hct and storage age of the blood product. Medical records of 86 patients (different for breed, gender and age) who received about 10-20 ml/kg of PRBC or FWB were collected at the Veterinary Teaching Hospital of the University of Montreal, Canada. The anemia was classified according to Hct, MCV, MCHC, \nand regeneration degree. The pre-transfusion Hct (T0) was compared to post-transfusion Hct \nat T1 (range 0-4h), T2 (4-16h), T3 (16-34h), T4 (34-50h) and T5 (more than 50h after transfusion) (Spearman test). The pre-transfusion Hct was compared to post-transfusion Hct \nin dogs with acute or chronic anemia transfused with either PRBC (n. 100) or SWB (n. 19). Furthermore, the influence of the storage and Hct of blood donor (blood products) used on post-transfusion Hct was assessed (Mann-Whitney test).The main cause for transfusion was \nacute and severe, macrocytic and hypochromic anemia with a moderate-high grade of \nregeneration due to hemorrhage. Pre-transfusion Hct of the recipient influenced the degree of \nthe increase of post-transfusion Hct only in chronic anemia (moderately inversely proportional at T1 and T4, rho >-0.500; and strongly inversely proportional at T5, rho <-0.600). The type of \nblood product did not affect post-transfusion Hct. There were no differences between the increases of Hct in recipient affected by acute or chronic anemia receiving blood products with different Hct values. The increase in Hct post-transfusion was greater when less than 10- \ndays old stored blood product was used (P=0.0329). In chronic anemia, lower pre-transfusion Hct was observed which was related with greater increase of post-transfusion Hct. In both chronic and acute anemias, both PRBC and SWB showed to be useful for improving the posttransfusion Hct. The use of blood products less than 10 days old was associated with a greater increase in post-transfusion Hct, possibly related to a greater viability of the transfusion cells less affected by "storage lesion".
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».