In Situ Re-Os Dating of Molybdenite Using La-Icp-Ms/Ms. Analytical protocol and standardization.
Notice bibliographique
Résumé
Dating with the Re-Os isotopic system provides several advantages compared to conventional\nchronometers such as Rb-Sr. Because of the sidero- and chalcophilic nature of Re and Os, those\ncan be found as trace elements in sulfides, meaning that ages can be obtained for sulfide deposit,\ngiving valuable information of ore genesis. To ensure the quality of the analytical measurements\nneeded in isotopic dating, a reference material with known concentrations of Re and Os is\nnecessary. The aim of this study is to develop a method to produce a homogenous tablet of the\nsulfide molybdenite, and validate its use as a reference material for calibration of in situ Re-Os\ndating using LA-ICP-MS/MS. Molybdenite from Kingsgate, Australia, was used as a test\nmaterial, molybdenite from Moly Hill, Canada, as the reference material for the tablet, and\nmolybdenite from Ytterby, Sweden, as a validation of the produced tablet. The molybdenite\nwas milled by hand with ethanol in an agate mortar and pressed into a tablet in a tablet die set\nby applying 2.5 t (0.19 × 106 kPa) for 2 min. Molybdenite proved to be hard to mill due to its\nlayered structure and milling in a high power planetary ball mill was therefore unsuccessful in\nproducing fine material. The optimum pressure and corresponding time depended on several\nfactors, such as the tablet die set and material, and will affect for example numbers of cracks in\nthe tablet. The tablet was analyzed with LA-ICP-MS/MS, an analytical method that was chosen\nbecause it provides the opportunity to target specific ions, created after a reaction with a reaction\ngas, in this case CH4. This is a tool used to chemically separate the parent and daughter isotopes\nand overcome the isobaric overlap. Isotopes of Re and Os, as well as potential elements in\ninclusion, was measured. Despite signs of inclusions in the final tablets, the Re and Os signals\nseemed unaffected by this. Ratios for 187Re/187Os was calculated for the tablet of molybdenite\nfrom Moly Hill, and for Ytterby molybdenite. The literature Re-Os age for Moly Hill, 2646 Ma,\nwas used to obtain a corresponding 187Re/187Os ratio, which in turn could be used to calculate a\ncorrection factor. This was applied to the Ytterby molybdenite to obtain corrected ratios, then\ncalculating an age of 1823 ± 28 Ma, which overlaps the literature age for Ytterby, 1795 ± 2 Ma.\nThe results validate the quality of the tablet produced of molybdenite from Moly Hill and\nconfirms that it can be used for calibration of in situ Re-Os dating with LA-ICP-MS/MS, even\nif several improvements of the methods can be done in the future, both in the milling process\nand the analytical process.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,010 | 0,004 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».