Enregistrement W7045689084

CFC-11 amount in polyurethane foam in end-of-life refrigerators

2012· other· tr· W7045689084 sur OpenAlexaboutno aff

Notice bibliographique

RevueMarmara University Open Access System · 2012
Typeother
Languetr
DomaineEngineering
ThématiqueRefrigeration and Air Conditioning Technologies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésPolyurethaneContext (archaeology)SeasonalityAir temperature
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

ÖMRÜNÜ TAMAMLAMIŞ BUZDOLAPLARINDA BULUNAN POLİÜRETAN KÖPÜKTEKİ CFC-11 MİKTARI\nBuzdolapları yaygın olarak kullanılan beyaz eşyalar arasındadır. Önemli unsurların başında gelen yalıtım; poliol, izosiyanat ve kabartıcının karışımından oluşan poliüretan köpük ile gerçekleştirilir. Kabartıcı, ısı transferini engeller ve enerji tüketimini azaltır. CFC-11, ozon tüketme potansiyeli belirlene kadar kabartıcı olarak kullanılmıştır. Sonrasında ise kullanımı Montreal Protokolü ile kısıtlanmıştır. Günümüzde, CFC-11 ve CFC-11 içeren maddeler “Ozon Tabakasını İncelten Maddeler” ve “Atık Yönetimi Genel Esaslarına İlişkin Yönetmelik” ile düzenlenmektedir. Buna ek olarak, “Atık Elektrikli ve Elektronik Ekipmanların Kontrolü Yönetmeliği” de taslak halinde olup, yakında yürürlüğe girecektir. Fakat buzdolaplarındaki PU köpük içindeki CFC-11 miktarı bilinmemektedir. Bu nedenle, bu çalışma 1996 öncesi üretilmiş ve halen kullanımda olan buzdolaplarındaki CFC-11 miktarını ve buna ilişkin ozon tüketme potansiyelini tespit etmek için gerçekleştirilmiştir. CFC-11 içeren buzdolabı miktarını tespit etmek için 1986-1995 arası üretilmiş buzdolabı iç satış verileri incelenmiş, basit bir model yardımıyla, 2,24 milyon buzdolabının halen kullanımda olduğu belirlenmiştir. Bir buzdolabında 4 kg yalıtım köpüğü bulunduğu göz önüne alınarak, CFC-11 içeren toplam PU köpük miktarı 8944 ton olarak hesaplanmıştır. 1996 öncesi üretilmiş, halen kullanımda olan buzdolaplarındaki PU köpük içindeki CFC-11 miktarını belirlemek için, ömrünü tamamlamış bir buzdolabından köpük numuneleri alınmış ve bu numunelerin CFC-11 içeriği ölçülmüştür. Köpük numuneleri ağzı kapalı bir şişede, 140oC sıcaklıkta 48 saat bekletilerek CFC-11 açığa çıkartılmış ve GC-MS ile analiz edilmiştir. Sonuç olarak, Türkiye’de, 1996 öncesi üretilmiş ve halen kullanımda olan buzdolabı miktarı 2,24 milyon olarak kabul edildiğinde, buzdolaplarında, yalıtım köpüğünde bulunan toplam CFC-11 miktarının 1011-1078 ton olması beklenmektedir. \n\nABSTRACT\nCFC-11 AMOUNT IN POLYURETHANE FOAM IN END-OF-LIFE REFRIGERATORS\nRefrigerators are among the most widely used household appliances. Insulation is of key importance which is accomplished by polyurethane (PU) foams consisting of a mixture of polyols, isocyanates and blowing agents. Blowing agent limits heat transfer and reduces energy consumption. CFC-11 (trichlorofluoromethane) had been used as blowing agent until its ozone depleting potential was discovered. Its use was then restricted with the Montreal Protocol. Today, CFC-11 and CFC-11 containing substances are regulated under “Directive on Ozone Depleting Substances” and “Regulation for General Principles of Waste Management” in Turkey. In addition, “Waste Electrical and Electronic Equipment Control Regulation” has been prepared and shall enter into force soon. However, the total amount of CFC-11 in PU insulation foam of refrigerators is not certainly known in Turkey. Therefore, this study was conducted to ascertain the amount of CFC-11 in pre-1996 refrigerators in-use and the related ozone depleting potential. Total number of refrigerators containing CFC-11 was determined from domestic sales data for years between 1986 and 1995, and using a survival function, it was obtained that 2.24 million of these refrigerators are still in use. Assuming 4 kg of insulation foam per refrigerator, the total amount of PU foam blown with CFC-11 was calculated as 8944 tons. In order to estimate the amount of CFC-11 in PU foam of pre-1996 refrigerators in-use, foam samples were taken from an obsolete refrigerator and their CFC-11 content was measured. CFC-11 was released by heating the foam samples to 140oC for 48 hours in a closed bottle and analyzed in the headspace using a GC-MS. As a result, by assuming that 2.24-million pre-1996 refrigerators are still in-use, the total amount of CFC-11 in insulation foam of refrigerators in Turkey was estimated to be 1011-1078 tons.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,792
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0020,002
Études des sciences et des technologies0,0000,000
Communication savante0,0010,002
Science ouverte0,0040,002
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0020,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,034
Tête enseignante GPT0,280
Écart entre enseignants0,246 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeSans objet
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2012
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueMarmara University Open Access SystemMême sujetRefrigeration and Air Conditioning TechnologiesTravaux en français237 207