MétaCan
Menu
Retour à la cohorte
Enregistrement W827398437

Experimental Evaluation Of Large Scale Propane Heat Pump For Space Heating Application

2015· article· en· W827398437 sur OpenAlexaboutno aff
Salvatore Piscopiello

Notice bibliographique

RevueKTH Publication Database DiVA (KTH Royal Institute of Technology) · 2015
Typearticle
Langueen
DomaineEngineering
ThématiqueRefrigeration and Air Conditioning Technologies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésRefrigerantHeat pumpPropaneWork (physics)Flammable liquidEnvironmental scienceAir source heat pumpsCoefficient of performanceHeat pump and refrigeration cycleMechanical engineeringProcess engineeringEngineeringComputer sciencePetroleum engineeringThermodynamicsHeat exchangerWaste managementPhysics
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

A significant part of the environmental impact of a heat pump isgenerally related to the direct emission of the refrigerant fluid during thelife time of the machine. Although the Montreal Protocol has alreadylargely secured its status as a success story by cutting the ozone deplentationrefrigerants drastically, we still have to deal with the challengesresulting from climate change.Natural refrigerants such as Propane permits to design more ecofriendlysystem without sacrificing the performance of the machine. Thethesis work is part of a European project called Next Generation of HeatPumps working with Natural fluids (NxtHPG) whose primary aim is thedevelopment of heat pumps working with Natural refrigerant that aresafe, reliable, with high efficiency and high capacity. Royal Institute oftechnology (KTH) is one of the partner of the project and responsiblefor the experimental campaign of two large propane heat pumps: an airsource heat pump (Case 1 ) and a ground source heat pump suitablefor boreholes (Case 2 ). Few cases in literature report on studies aboutlarge capacity heat pumps using propane as refrigerant.This thesis project focuses on the experimental evaluation of theCase 2 from an energy point view. The safety issues about the use of flammable refrigerant, i.e propane, are briefly reported; however theyare not considered strictly part of the thesis work since they are coveredin other phases of NxtHPG project. Experimental tests for Case 1 werenot conducted during this thesis work because of delays in the prototypedelivery from the manufacturer. However, concerns about the hydraulicloop of the test rig of both the heat pumps was identified and a newdesign was suggested and implemented.During the experimental campaign for Case 2 a significant numberof tests were performed according to a specific text matrix definedfrom the EN 14285 standard. A simple heat pump model has beenused to evaluate the overall performance of the machine from the directmeasurements. The heat pump components (compressors, condenser,evaporator, expansion valve) have been analysed in details by definingspecific analysis model for each one. The results have been comparedwith the manufacture expectation.The prototypes demonstrated to have potentially very good performance,since in the first set of tests the machine behaved as expectedby the IMST-ART software. On the other hand, a drop of the unitefficiency and capacity have been registered during the experimentalcampaign for similar working condition. Two different explanations areinvestigated to clarify the strange phenomenon. The first hypothesisconsiders minor internal damage in the compressor, as check valve leakage;consequence of the use of the compressor in a tandem layout. Itgenerates a back-flow in the non working compressor. The second explanationregards inert gas infiltration in the system. On the otherhand they are not able to explain entirely the system issues and theyneed to be confirmed by the manufacturer analysis of the open compressor.The further improvements, proposed and discussed with themanufacture companies involved, can help to solve the question markson the strange system behaviour during the future work. The nextexperimental campaign for Case 1 that will start on April 2015.The software IMST-ART, used to predict the performance of theheat pump, is demonstrated to be a fast and useful tool. The model ofthe software for propane as refrigerant and brazed plate heat exchangerpredicts adequately the experimental measurement.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,330
Score d'incertitude au seuil0,835

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,001
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,001
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,038
Tête enseignante GPT0,307
Écart entre enseignants0,269 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2015
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueKTH Publication Database DiVA (KTH Royal Institute of Technology)Même sujetRefrigeration and Air Conditioning TechnologiesTravaux en français237 207