MétaCan
Menu
Back to cohort
Record W827398437

Experimental Evaluation Of Large Scale Propane Heat Pump For Space Heating Application

2015· article· en· W827398437 on OpenAlexaboutno aff
Salvatore Piscopiello

Bibliographic record

VenueKTH Publication Database DiVA (KTH Royal Institute of Technology) · 2015
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsRefrigerantHeat pumpPropaneWork (physics)Flammable liquidEnvironmental scienceAir source heat pumpsCoefficient of performanceHeat pump and refrigeration cycleMechanical engineeringProcess engineeringEngineeringComputer sciencePetroleum engineeringThermodynamicsHeat exchangerWaste managementPhysics
DOInot available

Abstract

fetched live from OpenAlex

A significant part of the environmental impact of a heat pump isgenerally related to the direct emission of the refrigerant fluid during thelife time of the machine. Although the Montreal Protocol has alreadylargely secured its status as a success story by cutting the ozone deplentationrefrigerants drastically, we still have to deal with the challengesresulting from climate change.Natural refrigerants such as Propane permits to design more ecofriendlysystem without sacrificing the performance of the machine. Thethesis work is part of a European project called Next Generation of HeatPumps working with Natural fluids (NxtHPG) whose primary aim is thedevelopment of heat pumps working with Natural refrigerant that aresafe, reliable, with high efficiency and high capacity. Royal Institute oftechnology (KTH) is one of the partner of the project and responsiblefor the experimental campaign of two large propane heat pumps: an airsource heat pump (Case 1 ) and a ground source heat pump suitablefor boreholes (Case 2 ). Few cases in literature report on studies aboutlarge capacity heat pumps using propane as refrigerant.This thesis project focuses on the experimental evaluation of theCase 2 from an energy point view. The safety issues about the use of flammable refrigerant, i.e propane, are briefly reported; however theyare not considered strictly part of the thesis work since they are coveredin other phases of NxtHPG project. Experimental tests for Case 1 werenot conducted during this thesis work because of delays in the prototypedelivery from the manufacturer. However, concerns about the hydraulicloop of the test rig of both the heat pumps was identified and a newdesign was suggested and implemented.During the experimental campaign for Case 2 a significant numberof tests were performed according to a specific text matrix definedfrom the EN 14285 standard. A simple heat pump model has beenused to evaluate the overall performance of the machine from the directmeasurements. The heat pump components (compressors, condenser,evaporator, expansion valve) have been analysed in details by definingspecific analysis model for each one. The results have been comparedwith the manufacture expectation.The prototypes demonstrated to have potentially very good performance,since in the first set of tests the machine behaved as expectedby the IMST-ART software. On the other hand, a drop of the unitefficiency and capacity have been registered during the experimentalcampaign for similar working condition. Two different explanations areinvestigated to clarify the strange phenomenon. The first hypothesisconsiders minor internal damage in the compressor, as check valve leakage;consequence of the use of the compressor in a tandem layout. Itgenerates a back-flow in the non working compressor. The second explanationregards inert gas infiltration in the system. On the otherhand they are not able to explain entirely the system issues and theyneed to be confirmed by the manufacturer analysis of the open compressor.The further improvements, proposed and discussed with themanufacture companies involved, can help to solve the question markson the strange system behaviour during the future work. The nextexperimental campaign for Case 1 that will start on April 2015.The software IMST-ART, used to predict the performance of theheat pump, is demonstrated to be a fast and useful tool. The model ofthe software for propane as refrigerant and brazed plate heat exchangerpredicts adequately the experimental measurement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.330
Threshold uncertainty score0.835

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.307
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueKTH Publication Database DiVA (KTH Royal Institute of Technology)Same topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207