MétaCan
Menu
Back to cohort
Record W113783064

A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks.

2007· article· en· W113783064 on OpenAlexaff
Sara A. Alfadda, George A. Zarb, Yoav Finer

Bibliographic record

VenuePubMed · 2007
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsDistortion (music)Materials scienceSagittal planeImplantTitaniumBiomedical engineeringFabricationEngineering drawingComputer scienceEngineeringMetallurgySurgeryOptoelectronicsMedicine
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE: To compare the in vitro 3-dimensional (3D) accuracy of fit of laser-scanned Computer Numeric Controlled (CNC)-milled implant titanium frameworks to that of conventional cast frameworks. MATERIALS AND METHODS: Nine cast frameworks were fabricated on the mandibular master casts of 9 patients with 5 implants each following the well-established conventional fabrication technique. The frameworks were then laser scanned, and 9 CNC-milled titanium frameworks matching the outline of the conventional frameworks were fabricated. The accuracy of fit of both framework types was measured using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Statistical analysis was done by a series of paired ttests. RESULTS: The laser-scanned CNC-milled frameworks showed significantly less distortion along the x-axis (transversal, d(x)) compared with the conventional frameworks (means: 33.7 microm and 49.2 microm, respectively) (P = .011). The titanium frameworks also demonstrated significantly less distortion on the horizontal plane compared with the conventional frameworks (means: 56 microm and 85 microm, respectively) (P = .012). The d(y) (sagittal) and d(z) (vertical) axes and total 3D distortion (square root of dx(2) + dy(2) + dz(2)) showed less distortion overall in the laser-scanned CNC-milled frameworks, but this was not statistically significant (mean: 22.3 vs 35.6 microm, 13.3 vs 59.2 microm, 51 vs 114.1 microm, respectively, for y, z, and 3D distortion). CONCLUSION: Within the limitations of this study, fabrication of an implant-prosthodontic framework using the CNC milling technique yields a more accurate fit than the currently used cast technique. In vivo studies are needed to investigate the clinical significance of this recorded difference.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.012
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.128
GPT teacher head0.458
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations111
Published2007
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicDental Implant Techniques and OutcomesFrench-language works237,207