MétaCan
Menu
Back to cohort
Record W1246403004 · doi:10.1016/j.arthro.2015.06.027

Experimental Execution of the Simulated Pivot‐Shift Test: A Systematic Review of Techniques

2015· review· en· W1246403004 on OpenAlexaff
Fabio V. Arilla, Marco Yeung, Kevin M. Bell, Ata A. Rahnemai‐Azar, Benjamin B. Rothrauff, Freddie H. Fu, Richard E. Debski, Olufemi R. Ayeni, Volker Musahl

Bibliographic record

VenueArthroscopy The Journal of Arthroscopic and Related Surgery · 2015
Typereview
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsMcMaster University Medical Centre
Fundersnot available
KeywordsCadaveric spasmPivot-shift testRange of motionKinematicsComputer scienceSimulationMedicineSurgeryPhysicsAnterior cruciate ligament

Abstract

fetched live from OpenAlex

PURPOSE: To conduct a systematic review to identify and summarize the various techniques that have been used to simulate the pivot-shift test in vitro. METHODS: Medline, Embase, and the Cochrane Library were screened for studies involving the simulated pivot-shift test in human cadaveric knees published between 1946 and May 2014. Study parameters including sample size, study location, simulated pivot-shift technique, loads applied, knee flexion angles at which simulated pivot shift was tested, and kinematic evaluation tools were extracted and analyzed. RESULTS: Forty-eight studies reporting simulated pivot-shift testing on 627 cadaveric knees fulfilled the criteria. Reviewer inter-rater agreement for study selection showed a κ score of 0.960 (full-text review). Twenty-seven studies described the use of internal rotation torque, with a mean of 5.3 Nm (range, 1 to 18 Nm). Forty-seven studies described the use of valgus torque, with a mean of 8.8 Nm (range, 1 to 25 Nm). Four studies described the use of iliotibial tract tension, ranging from 10 to 88 N. Regarding static simulated pivot-shift test techniques, 100% of the studies performed testing at 30° of knee flexion, and the most tested range of motion in the continuous tests was 0° to 90°. Anterior tibial translation was the most analyzed parameter during the simulated pivot-shift test, being used in 45 studies. In 22% of the studies, a robotic system was used to simulate the pivot-shift test. Robotic systems were shown to have better control of the loading system and higher tracking system accuracy. CONCLUSIONS: This study provides a reference for investigators who desire to apply simulated pivot shift in their in vitro studies. It is recommended to simulate the pivot-shift test using a 10-Nm valgus torque and 5-Nm internal rotation torque. Knee flexion of 30° is mandatory for testing. LEVEL OF EVIDENCE: Level IV, systematic review of basic science studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.021
metaresearch head score (Gemma)0.102
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.021
Threshold uncertainty score0.110

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0210.102
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0110.010
Bibliometrics0.0140.012
Science and technology studies0.0010.002
Scholarly communication0.0040.004
Open science0.0030.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.324
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueArthroscopy The Journal of Arthroscopic and Related SurgerySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207