MétaCan
Menu
Back to cohort
Record W141291400

Exergy analysis of water loop heat pump system in an office building

2006· dissertation· en· W141291400 on OpenAlexaboutno aff
Xin Zheng

Bibliographic record

VenueSpectrum Research Repository (Concordia University) · 2006
Typedissertation
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsExergyHVACHeat pumpCoefficient of performanceExergy efficiencyEngineeringProcess engineeringAir conditioningEnergy recovery ventilationEnvironmental scienceElectricityHeat recovery ventilationTranscritical cycleChillerAbsorption heat pumpMechanical engineeringHeat exchangerThermodynamics
DOInot available

Abstract

fetched live from OpenAlex

HVAC systems have a significant contribution to the building energy demand and greenhouse gases emissions. The use of effective evaluation indicators and accurate analysis method are very important for improving the energy performance of HVAC systems. The second law of thermodynamics analysis is an appropriate approach to evaluate HVAC system performance. This thesis presents the second law of thermodynamics analysis of a Water Loop Heat Pump (WLHP) system, applied to a commercial building located in Montreal. This system allows for the heat recovered in the core zone to be used partially in the winter for heating the perimeter zones. The analysis covers both peak design and annual operating conditions. The following equipment is included in the analysis: the water-to-air heat pumps, the boiler, the water circulating pumps, the fan and the heat ejector (e.g., cooling tower). Primary and secondary energy sources are considered, for instance in the case of the generation of electricity. Mathematical models developed in this study are implemented in the Engineering Equations Solver (EES) environment. The performance of the WLHP system is evaluated using indicators such as: the energy and exergy efficiency, the energy and exergy demand, the exergy lost, and the equivalent CO 2 emissions due to the system operation. The results show that the exergy efficiency of the WLHP system has an annual average value of 2.8%. The annual average value of the Coefficient of Performance (COP) of the WLHP system is evaluated at 1.68. The major exergy destruction components of the WLHP system are the boiler, the heat pumps in core zone and the cooling tower

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.420
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0040.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.237
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueSpectrum Research Repository (Concordia University)Same topicBuilding Energy and Comfort OptimizationFrench-language works237,207