MétaCan
Menu
Back to cohort
Record W1496866851 · doi:10.3171/2014.7.gks141199

Standardization of terminology in stereotactic radiosurgery: Report from the Standardization Committee of the International Leksell Gamma Knife Society

2014· article· en· W1496866851 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of neurosurgery · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Toronto
FundersElekta
KeywordsMedicineRadiosurgeryNuclear medicineMedical physicsGamma knifeTerminologyRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

OBJECT: This report has been prepared to ensure more uniform reporting of Gamma Knife radiosurgery treatment parameters by identifying areas of controversy, confusion, or imprecision in terminology and recommending standards. METHODS: Several working group discussions supplemented by clarification via email allowed the elaboration of a series of provisional recommendations. These were also discussed in open session at the 16th International Leksell Gamma Knife Society Meeting in Sydney, Australia, in March 2012 and approved subject to certain revisions and the performance of an Internet vote for approval from the whole Society. This ballot was undertaken in September 2012. RESULTS: The recommendations in relation to volumes are that Gross Target Volume (GTV) should replace Target Volume (TV); Prescription Isodose Volume (PIV) should generally be used; the term Treated Target Volume (TTV) should replace TVPIV, GTV in PIV, and so forth; and the Volume of Accepted Tolerance Dose (VATD) should be used in place of irradiated volume. For dose prescription and measurement, the prescription dose should be supplemented by the Absorbed Dose, or DV% (for example, D95%), the maximum and minimum dose should be related to a specific tissue volume (for example, D2% or preferably D1 mm3), and the median dose (D50%) should be recorded routinely. The Integral Dose becomes the Total Absorbed Energy (TAE). In the assessment of planning quality, the use of the Target Coverage Ratio (TTV/ GTV), Paddick Conformity Index (PCI = TTV2/[GTV · PIV]), New Conformity Index (NCI = [GTV · PIV]/TTV2), Selectivity Index (TTV/PIV), Homogeneity Index (HI = [D2% –D98%]/D50%), and Gradient Index (GI = PIV0.5/PIV) are reemphasized. In relation to the dose to Organs at Risk (OARs), the emphasis is on dose volume recording of the VATD or the dose/volume limit (for example, V10) in most cases, with the additional use of a Maximum Dose to a small volume (such as 1 mm3) and/or a Point Dose and Mean Point Dose in certain circumstances, particularly when referring to serial organs. The recommendations were accepted by the International Leksell Gamma Knife Society by a vote of 92% to 8%. CONCLUSIONS: An agreed-upon and uniform terminology and subsequent standardization of certain methods and procedures will advance the clinical science of stereotactic radiosurgery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.315
Threshold uncertainty score0.300

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.256
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it