MétaCan
Menu
Back to cohort
Record W1502476404 · doi:10.1186/s12916-015-0396-2

A meta-analysis of the performance of the PimaTM CD4 for point of care testing

2015· review· en· W1502476404 on OpenAlexfundno aff
Lesley Scott, Jennifer Campbell, Larry E. Westerman, Luc Kestens, Lara Vojnov, Luciana Kohastsu, John N. Nkengasong, Trevor Peter, Wendy Stevens

Bibliographic record

VenueBMC Medicine · 2015
Typereview
Languageen
FieldMedicine
TopicHIV/AIDS Research and Interventions
Canadian institutionsnot available
FundersCenters for Disease Control and PreventionGrand Challenges CanadaU.S. President’s Emergency Plan for AIDS Relief
KeywordsMedicineConfidence intervalPoint-of-care testingBivariate analysisInternal medicinePoint of careMean differenceMeta-analysisUnivariate analysisImmunologyStatisticsPathologyMultivariate analysis

Abstract

fetched live from OpenAlex

BACKGROUND: The Alere point-of-care (POC) Pima™ CD4 analyzer allows for decentralized testing and expansion to testing antiretroviral therapy (ART) eligibility. A consortium conducted a pooled multi-data technical performance analysis of the Pima CD4. METHODS: Primary data (11,803 paired observations) comprised 22 independent studies between 2009-2012 from the Caribbean, Asia, Sub-Saharan Africa, USA and Europe, using 6 laboratory-based reference technologies. Data were analyzed as categorical (including binary) and numerical (absolute) observations using a bivariate and/or univariate random effects model when appropriate. RESULTS: At a median reference CD4 of 383 cells/μl the mean Pima CD4 bias is -23 cells/μl (average bias across all CD4 ranges is 10 % for venous and 15% for capillary testing). Sensitivity of the Pima CD4 is 93% (95% confidence interval [CI] 91.4% - 94.9%) at 350 cells/μl and 96% (CI 95.2% - 96.9%) at 500 cells/μl, with no significant difference between venous and capillary testing. Sensitivity reduced to 86% (CI 82% - 89%) at 100 cells/μl (for Cryptococcal antigen (CrAg) screening), with a significant difference between venous (88%, CI: 85% - 91%) and capillary (79%, CI: 73% - 84%) testing. Total CD4 misclassification is 2.3% cases at 100 cells/μl, 11.0% at 350 cells/μl and 9.5 % at 500 cells/μl, due to higher false positive rates which resulted in more patients identified for treatment. This increased by 1.2%, 2.8% and 1.8%, respectively, for capillary testing. There was no difference in Pima CD4 misclassification between the meta-analysis data and a population subset of HIV+ ART naïve individuals, nor in misclassification among operator cadres. The Pima CD4 was most similar to Beckman Coulter PanLeucogated CD4, Becton Dickinson FACSCalibur and FACSCount, and less similar to Partec CyFlow reference technologies. CONCLUSIONS: The Pima CD4 may be recommended using venous-derived specimens for screening (100 cells/μl) for reflex CrAg screening and for HIV ART eligibility at 350 cells/μl and 500 cells/μl thresholds using both capillary and venous derived specimens. These meta-analysis findings add to the knowledge of acceptance criteria of the Pima CD4 and future POC tests, but implementation and impact will require full costing analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.518
Threshold uncertainty score0.626

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0040.004
Bibliometrics0.0000.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.436
GPT teacher head0.476
Teacher spread0.040 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueBMC MedicineSame topicHIV/AIDS Research and InterventionsFrench-language works237,207