MétaCan
Menu
Back to cohort
Record W1525367846 · doi:10.1002/lary.24130

Evaluation of intraoperative cone beam computed tomography and optical drill tracking in temporal bone surgery

2013· article· en· W1525367846 on OpenAlexafffund
Boban M. Erović, Michael J. Daly, Harley Chan, Adrian L. James, Blake C. Papsin, David D. Pothier, Ben Dixon, Jonathan C. Irish

Bibliographic record

VenueThe Laryngoscope · 2013
Typearticle
Languageen
FieldMedicine
TopicMeningioma and schwannoma management
Canadian institutionsHospital for Sick ChildrenPrincess Margaret Cancer CentreOntario Institute for Cancer Research
FundersUniversity of Toronto
KeywordsCone beam computed tomographyDrillComputed tomographyTracking (education)MedicineDrill holeTomographyOpticsRadiologyMaterials sciencePhysics

Abstract

fetched live from OpenAlex

OBJECTIVES/HYPOTHESIS: A prototype system for intraoperative cone beam computed tomography (CBCT) imaging has been developed and augmented with real time optical tracking of a surgical drill. We hypothesize that this system provides sufficient accuracy for guidance of temporal bone surgery. STUDY DESIGN: Basic research. METHODS: Measurements of drill localization accuracy using CBCT imaging were obtained with a custom three-dimensional calibration object. Integrated CBCT imaging and drill tracking were prospectively evaluated on 12 cadaver temporal bones. Six inexperienced and six experienced surgeons conducted four surgical tasks: cortical mastoidectomy, posterior tympanotomy, cochleostomy, and a translabyrinthine approach to the internal auditory canal. Questionnaires provided expert feedback on tracking accuracy and system usability. RESULTS: Target registration error measurements of drill tracking accuracy and precision yielded a mean of 0.76 mm, a maximum of 1.30 mm, and a standard deviation of 0.21 mm. Anatomical landmark identification tasks (e.g., facial nerve, incus, semicircular canals, cochlea) provided additional validation of system accuracy. The usability and utility of the guidance system were positively rated by both groups of surgeons, with further modifications underway to improve tracking line of sight and registration workflow. Experienced but in particular inexperienced surgeons indicated significant benefits in cases involving extensive disease, abnormal anatomy, and loss of anatomical landmarks. CONCLUSIONS: The integration of intraoperative CBCT imaging with optical tracking provides sufficient accuracy to localize anatomical structures within the temporal bone using an otological drill. Future studies will explore the role of this technology in complex oncological resections, in surgery for congenital anomalies, and as a tool for teaching.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.313
Threshold uncertainty score0.302

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.290
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueThe LaryngoscopeSame topicMeningioma and schwannoma managementFrench-language works237,207