MétaCan
Menu
Back to cohort
Record W1531876209 · doi:10.1093/jaoac/88.1.182

Carrier Tests to Assess Microbicidal Activities of Chemical Disinfectants for Use on Medical Devices and Environmental Surfaces

2005· article· en· W1531876209 on OpenAlexaff
V. Susan Springthorpe, Syed A. Sattar

Bibliographic record

VenueJournal of AOAC International · 2005
Typearticle
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsHuman decontaminationDisinfectantContext (archaeology)MicrobicideBiochemical engineeringContaminationEnvironmental scienceComputer scienceMedicineWaste managementEngineeringBiologyPathology

Abstract

fetched live from OpenAlex

For well over a decade, many deficiencies have been identified in current AOAC methods used to assess the microbicidal activities of chemical disinfectants on medical devices and environmental surfaces. This report discusses the development of quantitative carrier tests (QCT) designed to address these concerns. Decontamination of surfaces with dried inocula is invariably more difficult than when microorganisms are in suspension. For medical device as well as environmental decontamination, microbicides are used on contaminated surfaces, thus making it necessary to evaluate their microbicidal action on representative carrier materials contaminated with a dried challenge microorganism(s). Our approach is a 2-tiered QCT. The first tier (QCT-1) uses relatively ideal conditions to assess performance of the microbicide for screening purposes; the test uses smooth glass surfaces and quantities of disinfectant in excess of those likely to be experienced in the field. The second tier of testing (QCT-2) is more stringent because it uses (1) disks of brushed stainless steel as carriers, (2) only 50 microL of the test formulation on each carrier as compared to 1 mL in QCT-1, and (3) an added soil load to simulate the presence of residual body fluids or accumulated surface dirt. This review also discusses the factors that affect disinfection of medical devices and environmental surfaces in the context of the methodology used to evaluate the potency of microbicides. Specific recommendations for discussion are included, and performance criteria are suggested based on a risk-reduction approach for different classes of disinfectants. The focus is on improving the relevance of the test methodology to actual field use of disinfectants for devices and facilities in health care, and potentially in other settings. It is hoped that this review and its recommendations will initiate needed discussion and resolution of the many issues identified.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.008
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0050.002
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.294
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations78
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueJournal of AOAC InternationalSame topicMedical Device Sterilization and DisinfectionFrench-language works237,207