MétaCan
Menu
Back to cohort
Record W1538890478 · doi:10.1111/joic.12043

Experience With the Atrium Advanta Covered Stent for Aortic Obstruction

2013· article· en· W1538890478 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Interventional Cardiology · 2013
Typearticle
Languageen
FieldMedicine
TopicCongenital Heart Disease Studies
Canadian institutionsToronto General HospitalUniversity of TorontoUniversity Health NetworkHospital for Sick Children
Fundersnot available
KeywordsMedicineStentCuffAngioplastyBalloonBlood pressureComplicationSurgeryCardiologyInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: We sought to assess the efficacy, safety and clinical outcomes of the Advanta V12™ covered stent in management of coarctation of the aorta (CoA). MATERIALS AND METHODS: Stent functionality was assessed by review of angiographic imaging, clinical data at admission, discharge and at the last clinic visit, stent configuration on chest roentgenogram, radiation exposure, and complications. RESULTS: Between October 2009 and February 2012, 17 patients underwent stent implantation. There were 9-12, 2-14, and 6-16 mm diameter stents deployed. Balloon angioplasty after implantation was required in 2 patients. Mean percent recoil in the middle of the stent for the 12, 14, and 16 mm implants was 14%, 24%, and 24%, respectively. There was improvement in CoA diameter from 6.6 ± 3.2 to 11.5 ± 1.7 mm (P<0.0001) and a reduction in the peak pressure gradient from 23.1 ± 10.1 to 0.8 ± 3.3 mmHg (P<0.0001). No patient had a symptomatic complication. Left arm cuff blood pressure fell 24 hours after implantation and left arm to leg blood pressure gradient fell to <20 mmHg in all (P<0.0001). Follow-up was a median 242 days and at the last clinic visit there were no statistically different findings from discharge. Five children (33%) required antihypertensive medications but 3 were off medication at latest follow-up. Three patients (18%) required reintervention. CONCLUSION: The implantation of the Advanta™ V12 stent for the treatment of CoA is safe and effective in the early term. However, further study is required to determine longer-term stent efficacy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.238
Threshold uncertainty score0.175

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.311
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it