MétaCan
Menu
← Back to cohort
Record W1547114839 · doi:10.1111/cid.12134

A Photoelastic Stress Analysis of Screw‐ and Cement‐Retained Implant Prostheses with Marginal Gaps

2013· article· en· W1547114839 on OpenAlexvenueno aff
Jae‐In Lee, Yoon Lee, N.Y Kim, Yu‐Lee Kim, Hye‐Won Cho

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2013
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMaterials scienceImplantOsseointegrationPremolarDentistryProsthesisStress (linguistics)Dental prosthesisMolarCementDental AbutmentsOrthodonticsComposite materialMedicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The precise fit of an implant prosthesis is considered to be a prerequisite for the success and maintenance of osseointegration. It is unknown how much static stress can be tolerated at the implant-bone interface with ill-fitting prostheses for the two different types of retention (cement vs screw). PURPOSE: The purpose of this study was to evaluate the stress pattern and magnitude in the supporting tissues around ITI (Straumann AG, Waldenburg, Switzerland) implants with screw- or cement-retained prostheses with marginal gaps by photoelastic analysis. MATERIALS AND METHODS: A photoelastic model of a human mandible, partially edentulous distal to the canine, was made of PL-2 resin. Three ITI implants (4.1 × 10 mm, Straumann AG, Waldenburg, Switzerland) were placed in the posterior edentulous region, and screw- or cement-retained three-unit fixed partial dentures (FPDs) were fabricated. Ill-fitting prostheses were made by placing a 100-μm gap between the abutments and the superstructures on the second premolar or the first molar. A static vertical force of 134 N was applied at three loading points on each prosthesis. Photoelastic stress analysis was carried out to measure the fringe order around the implant-supporting structures. RESULTS: Even in the unloaded condition, low-level stresses were generated around the implants after screw tightening or cementing the three-unit FPDs with marginal gaps. Loading on the terminal implants developed high concentrated stresses around the loaded implant, regardless of the types of restorations or the presence of gaps. However, when the middle implant was loaded, moderate stresses were distributed to the anterior and posterior implants. CONCLUSIONS: Screw-retained FPDs with gaps exhibited a wider range of stresses on the interproximal region of adjacent implants than cement-retained FPDs. However, severe misfit in the prosthesis caused the nonaxial stress transfer to the adjacent implants in the cement-retained FPDs with gaps.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.422
Teacher spread0.344 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→