MétaCan
Menu
← Back to cohort
Record W1557585742 · doi:10.25011/cim.v30i3.1751

Attenuation of the Threshold for Myocardial Ischemia in Ramp vs Standard Bruce Protocol in Patients with Positive Exercise Stress Test and Angiographically Demonstrated Coronary Artery Narrowing?

2007· article· en· W1557585742 on OpenAlexaffvenue
Martin Noël, Jean Jobin, Audrey Marcoux, L Boyer, Gilles R. Dagenais, Peter Bogaty

Bibliographic record

VenueClinical and investigative medicine · 2007
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsUniversité LavalInstitut universitaire de cardiologie et de pneumologie de Québec
Fundersnot available
KeywordsBruce protocolMedicineCardiologyInternal medicineCoronary artery diseaseHeart rateIschemiaST depressionHemodynamicsStress testing (software)Blood pressureST segmentMyocardial infarction

Abstract

fetched live from OpenAlex

Background: Gradual instead of abrupt increases in workload favour a more physiological response in terms of hemodynamic and gas exchange parameters. Therefore, we sought to determine whether myocardial ischemia is attenuated with a ramp compared to a standard Bruce exercise protocol in patients with coronary artery disease (CAD). Methods: We compared ischemic parameters on the Bruce protocol with an individualized ergocycle ramp protocol in 18 men with documented CAD (≥ 70% stenosis) and a reproducible ischemic ECG exercise test. These 2 symptom-limited tests were performed in random order 2 weeks apart. Oxygen consumption (VO2), ischemic threshold [systolic blood pressure x heart rate (RPP) at 1 mm ST-segment depression], and maximum ST-segment depression corresponding to the highest RPP common to the 2 tests (AdjSTmax) were determined. Results: While all subjects showed ischemia on the treadmill, 6/18 did not on the ergocycle. However, ischemic threshold was higher on the ramp than the Bruce protocol (23 420 ± 5 732 vs 20 018 ± 3 542 bpm•min-1•mmHg; P=0.007). Peak RPP was higher during the ramp than with the Bruce protocol (28 492 ± 6 450 vs 25 519 ± 6 067 bpm•min-1•mmHg, respectively; P=0.02), despite similar peak VO2 (25.59 ± 5.05 vs 26.39 ± 4.65 mlO2•kg-1•min-1, respectively; P=0.6). AdjSTmax was less on the ramp than the Bruce protocol (-1.2 ± 0.9 vs -1.9 ± 0.7 mm; P=0.003). Conclusion: Exercise-induced myocardial ischemia is markedly attenuated on the more gradually increasing workload of the individualized ramp ergocycle compared with the standard Bruce treadmill protocol. This effect is unexplained by energy expenditure (VO2) or myocardial work (RPP) and is consistent with a “warm-up” ischemic mechanism. The more gradually increasing workload of the ramp ergocycle protocol may have favoured a “warm-up” ischemic effect despite achieving higher RPP than the Bruce protocol treadmill suggesting it may be physiologically preferable for exercise prescription in patients with CAD.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.298
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueClinical and investigative medicine→Same topicCardiovascular and exercise physiology→French-language works237,207→