MétaCan
Menu
Back to cohort
Record W1562309261 · doi:10.1186/1748-7161-10-s1-o60

How does pressure configuration affect Cobb angle during AIS brace casting?

2015· article· en· W1562309261 on OpenAlexaff
Eric Chalmers, Doug Hill, Andreas Donauer, Melissa Tilburn, Vicky Zhao, Edmond Lou

Bibliographic record

VenueScoliosis · 2015
Typearticle
Languageen
FieldMedicine
TopicScoliosis diagnosis and treatment
Canadian institutionsAlberta Health ServicesUniversity of Alberta
Fundersnot available
KeywordsCobb angleBraceCobBUltrasoundTorqueLinear regressionOutlierMedicineScoliosisBiomedical engineeringOrthodonticsMathematicsNuclear medicineSurgeryStatisticsStructural engineeringPhysicsEngineeringRadiology

Abstract

fetched live from OpenAlex

This work measured the magnitude and distance between pressures applied to the torso of AIS patients by an orthotist during brace casting. The instantaneous effect of the pressure configuration on Cobb angle was investigated using ultrasound. The objective was to use real-time measurements to confirm that pressure configuration affects Cobb angle predictably. Nine AIS patients undergoing casting for new braces participated in this pilot study (2 males, 7 females, aged 11-16, Cobb angles 16-44 degrees). An ultrasound scan was used to measure the patient's (baseline) Cobb angle. The orthotist then used a custom standing Providence system to apply corrective pressures - simulating a brace. A second ultrasound scan measured the new (corrected) Cobb angle. The orthotist could then try to achieve additional correction by adjusting the pressure magnitude/location. The process of adjusting pressures and ultrasound scanning repeated two or three times; the orthotist then chose the most satisfactory pressure configuration and performed the actual casting. The procedure produced 26 individual scans (including baseline scans) from the 9 patients. The magnitude of applied pressures was measured using inflatable air bladders fixed to the Providence pads. The air pressure was measured during the ultrasound scan. The distance between pads was measured and multiplied by the total pressure to create a torque-like measurement. Robust linear regression was used to relate pressure with Cobb angle correction, and torque with correction. Outlier points were removed if they fell more than 1.5 standard deviations from the regression line. Correlations between pressure/torque and correction were then measured. Two outlier points were removed - both belonging to a single patient. Pressures ranged from 16-113 mmHg. The major curves' correction ranged from 0-39%. Significant correlations existed between average pressure and Cobb angle correction (r = 0.86, p < 0.01), and average torque and Cobb angle correction (r = 0.82, p < 0.01). Cobb angle correction can be increased by increasing the applied pressure. Curves which allow larger spacing between the pressure pads should also expect larger correction. This pilot study is the first to validate these concepts in real-time using noninvasive ultrasound technology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.359
Threshold uncertainty score0.661

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.288
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueScoliosisSame topicScoliosis diagnosis and treatmentFrench-language works237,207