MétaCan
Menu
Back to cohort

Anesthesia for noncardiac procedures for children with a Berlin Heart EXCOR® Pediatric Ventricular Assist Device: a case series

2010· article· en· W1574984369 on OpenAlexaff
Dominic Cave, KATHRYN M. FRY, Holger Buchholz

Bibliographic record

VenuePediatric Anesthesia · 2010
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsStollery Children's HospitalUniversity of Alberta
Fundersnot available
KeywordsMedicinePerioperativeAnesthesiaPopulationOdds ratioAnestheticVentricular assist deviceHeart failureInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: To report our experience of providing anesthesia for noncardiac procedures in children with in situ Berlin Heart EXCOR Pediatric ventricular assist devices and to suggest principles of anesthetic management. BACKGROUND: With the initiation of the first North American training and support center for Berlin Heart at our institution in 2006, we have been asked to provide anesthesia for noncardiac procedures to these children. No current anesthetic approach to these children has been reported. METHODS/MATERIALS: Anesthetic records for all noncardiac procedures for children with Berlin Heart between August 2006 and February 2009 in a tertiary care pediatric hospital were retrospectively reviewed. Charts were reviewed for demographic and clinical data, perioperative management, and occurrence of hypotension. RESULTS: Twenty-nine procedures were performed on 11 patients. Hypotension was a common occurrence with all anesthetic induction and maintenance agents even at low doses. Ketamine induction, however, was less likely to produce hypotension, odds ratio for hypotension 0.1333 (95% confidence range 0.021-0.856). Hypotension was responsive to fluid bolus (60%) and alpha-receptor agonists (100%). Preoperative stability and presence of biventricular ventricular assist device (BiVAD) did not predict intraoperative hemodynamic course. CONCLUSIONS: Unlike patients with other ventricular assist devices, these children do not tolerate reductions in systemic vascular resistance (SVR) because of the relatively fixed cardiac output of this device. Agents that reduce SVR should be avoided where possible. Preoperative stability is not predictive. Fluids and alpha-agonists should be first-line response to hypotension in this population. Further study of this unusual population is warranted to further delineate best anesthetic practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.370
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.218
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2010
Admission routes1
Has abstractyes

Explore more

Same venuePediatric AnesthesiaSame topicMechanical Circulatory Support DevicesFrench-language works237,207