MétaCan
Menu
Back to cohort
Record W1576649547 · doi:10.1186/cc4912

Kinetic bed therapy to prevent nosocomial pneumonia in mechanically ventilated patients: a systematic review and meta-analysis

2006· review· en· W1576649547 on OpenAlexaff
Anthony Delaney, Hilary Gray, Kevin B. Laupland, Danny J. Zuege

Bibliographic record

VenueCritical Care · 2006
Typereview
Languageen
FieldMedicine
TopicNosocomial Infections in ICU
Canadian institutionsUniversity of CalgaryAlberta Health Services
Fundersnot available
KeywordsMedicineIntensive care medicinePneumoniaMeta-analysisVentilator-associated pneumoniaMechanical ventilationEmergency medicineInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: Nosocomial pneumonia is the most important infectious complication in patients admitted to intensive care units. Kinetic bed therapy may reduce the incidence of nosocomial pneumonia in mechanically ventilated patients. The objective of this study was to investigate whether kinetic bed therapy reduces the incidence of nosocomial pneumonia and improves outcomes in critically ill mechanically ventilated patients. METHODS: We searched Medline, EMBASE, CINAHL, CENTRAL, and AMED for studies, as well as reviewed abstracts of conference proceedings, bibliographies of included studies and review articles and contacted the manufacturers of medical beds. Studies included were randomized or pseudo-randomized clinical trials of kinetic bed therapy compared to standard manual turning in critically ill mechanically ventilated adult patients. Two reviewers independently applied the study selection criteria and extracted data regarding study validity, type of bed used, intensity of kinetic therapy, and population under investigation. Outcomes assessed included the incidence of nosocomial pneumonia, mortality, duration of ventilation, and intensive care unit and hospital length of stay. RESULTS: Fifteen prospective clinical trials were identified, which included a total of 1,169 participants. No trial met all the validity criteria. There was a significant reduction in the incidence of nosocomial pneumonia (pooled odds ratio (OR) 0.38, 95% confidence interval (CI) 0.28 to 0.53), but no reduction in mortality (pooled OR 0.96, 95%CI 0.66 to 1.14), duration of mechanical ventilation (pooled standardized mean difference (SMD) -0.14 days, 95%CI, -0.29 to 0.02), duration of intensive care unit stay (pooled SMD -0.064 days, 95% CI, -0.21 to 0.086) or duration of hospital stay (pooled SMD 0.05 days, 95% CI -0.18 to 0.27). CONCLUSION: While kinetic bed therapy has been purported to reduce the incidence of nosocomial pneumonia in mechanically ventilated patients, the overall body of evidence is insufficient to support this conclusion. There appears to be a reduction in the incidence of nosocomial pneumonia, but no effect on mortality, duration of mechanical ventilation, or intensive care or hospital length of stay. Given the lack of consistent benefit and the poor methodological quality of the trials included in this analysis, definitive recommendations regarding the use of this therapy cannot be made at this time.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.910
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0100.003
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.412
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations108
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueCritical CareSame topicNosocomial Infections in ICUFrench-language works237,207