MétaCan
Menu
← Back to cohort

Immediate/Early Function of Neoss Implants Placed in Maxillas and Posterior Mandibles: An 18‐Month Prospective Case Series Study

2008· article· en· W1579347719 on OpenAlexvenueno aff
Leonardo Vanden Bogaerde, Giorgio Pedretti, Lars Sennerby, Neil Meredith

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2008
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineImplant stability quotientResonance frequency analysisMaxillaImplantDentistryMandible (arthropod mouthpart)RadiographyProsthesisDental prosthesisOsseointegrationSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: An increasing number of studies show that immediate/early function of dental implants can be as successful as two-stage procedures. However, the results may not be universal for all implant types and it is important that new implants are tested for this treatment modality. PURPOSE: The aim was to evaluate an immediate/early function protocol in the maxilla and in the posterior mandible using Neoss implants (Neoss Ltd., Harrogate, UK). MATERIALS AND METHODS: A total of 21 patients were provided with 69 Neoss implants (4 mm in diameter and 9-15 mm in length) and a provisional bridge within 7 days (mean 4.6 days). Sixteen implants were placed in immediate extraction sites where seven were treated with autologous bone grafts (n = 6) or bone grafts + resorbable membrane (n = 1). A final fixed prosthesis was made 3 to 6 months later. The patients were followed-up with clinical examinations for 18 months. In addition, the implants were monitored with resonance frequency analysis (RFA) measurements at surgery and after 1, 2, and 6 months. Intraoral radiographs were taken after surgery and after 1, 6, and 18 months. RESULTS: One implant in an extraction site in the maxilla failed after 1 month, giving a survival rate of 98.5% after 18 months. The mean marginal bone loss was 0.7 mm (SD 0.7) after 18 months. RFA showed a mean implant stability quotient (ISQ) value of 68.1 (SD 8.8) at surgery, which increased to 73.7 (SD 5.7) after 6 months. The primary stability for maxillary and mandibular implants was similar, although mandibular implants showed slightly higher values with time. Implants in extraction sockets showed a lower initial stability than in healed sites, ISQ 65.8 (SD 7.5), which increased to ISQ 67.5 (SD 6.9) after 6 months. The failed implant showed an ISQ of 74 at placement, which decreased to 42 1 month after surgery. CONCLUSION: Within the limitations of the present study, it is concluded that immediate/early function with Neoss implants is a reliable method with an implant survival rate comparable to that of the traditional two-stage protocol.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.447
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→