MétaCan
Menu
Back to cohort
Record W1580524263 · doi:10.1111/trf.12679

A quality monitoring program for red blood cell components: in vitro quality indicators before and after implementation of semiautomated processing

2014· article· en· W1580524263 on OpenAlexafffundabout
Jason P. Acker, Adele Hansen, Jayme Kurach, Tracey R. Turner, Ioana M. Croteau, Craig Jenkins

Bibliographic record

VenueTransfusion · 2014
Typearticle
Languageen
FieldMedicine
TopicBlood transfusion and management
Canadian institutionsCanadian Blood ServicesUniversity of Alberta
FundersCanadian Blood Services
KeywordsHemolysisHematocritHemoglobinRed blood cellBlood componentBuffy coatWhole bloodAndrologyChemistryMedicineBiochemistryImmunologyInternal medicineEmergency medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Canadian Blood Services has been conducting quality monitoring of red blood cell (RBC) components since 2005, a period spanning the implementation of semiautomated component production. The aim was to compare the quality of RBC components produced before and after this production method change. STUDY DESIGN AND METHODS: Data from 572 RBC units were analyzed, categorized by production method: Method 1, RBC units produced by manual production methods; Method 2, RBC units produced by semiautomated production and the buffy coat method; and Method 3, RBC units produced by semiautomated production and the whole blood filtration method. RBC units were assessed using an extensive panel of in vitro tests, encompassing regulated quality control criteria such as hematocrit (Hct), hemolysis, and hemoglobin (Hb) levels, as well as adenosine triphosphate, 2,3-diphosphoglycerate, extracellular K(+) and Na(+) levels, methemoglobin, p50, RBC indices, and morphology. RESULTS: Throughout the study, all RBC units met mandated Canadian Standards Association guidelines for Hb and Hct, and most (>99%) met hemolysis requirements. However, there were significant differences among RBC units produced using different methods. Hb content was significantly lower in RBC units produced by Method 2 (51.5 ± 5.6 g/unit; p < 0.001). At expiry, hemolysis was lowest in Method 2-produced RBC units (p < 0.05) and extracellular K(+) levels were lowest in units produced by Method 1 (p < 0.001). CONCLUSION: While overall quality was similar before and after the production method change, the observed differences, although small, indicate a lack of equivalency across RBC products manufactured by different methods.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.471
Threshold uncertainty score0.553

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.344
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations106
Published2014
Admission routes3
Has abstractyes

Explore more

Same venueTransfusionSame topicBlood transfusion and managementFrench-language works237,207