MétaCan
Menu
Back to cohort
Record W1652689066 · doi:10.5858/2002-126-1494-eoadha

Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer.

2002· article· en· W1652689066 on OpenAlexaffabout
John Lafferty, Andrew McFarlane, David H.K. Chui

Bibliographic record

VenuePubMed · 2002
Typearticle
Languageen
FieldMedicine
TopicHemoglobinopathies and Related Disorders
Canadian institutionsMcMaster UniversityHamilton Health SciencesHamilton Regional Laboratory Medicine Program
Fundersnot available
KeywordsHemoglobinopathyHemoglobin variantsHemoglobinContext (archaeology)MedicineSpectrum analyzerLinearityLinear regressionHemoglobin ALinear correlationChromatographyStatisticsInternal medicineHemolytic anemiaChemistryMathematicsComputer scienceBiology

Abstract

fetched live from OpenAlex

CONTEXT: Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. OBJECTIVE: Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobinopathy investigation on a single kit. DESIGN: We evaluated Hb A(1c), Hb A(2), and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. SETTING: Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. PATIENTS: Patient blood samples submitted for Hb A(1c) quantitation or hemoglobinopathy investigation. MAIN OUTCOME MEASURES: Precision, linearity, linear regression, and reference interval validation. RESULTS: We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A(1c), Hb A(2), and Hb F. CONCLUSIONS: The dual kit provides precise Hb A(1c), Hb A(2), and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A(1c) using the beta-Thal method; and eliminates the need for separate Hb A(2) reference intervals for patients with Hb S because of its accurate quantitation of Hb A(2) in the presence of Hb S.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.021
Threshold uncertainty score0.042

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.008
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.055
GPT teacher head0.267
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2002
Admission routes2
Has abstractyes

Explore more

Same venuePubMedSame topicHemoglobinopathies and Related DisordersFrench-language works237,207