MétaCan
Menu
Back to cohort
Record W1715989194 · doi:10.1159/000437214

In vitro Detection of Occlusal Caries on Permanent Teeth by a Visual, Light-Induced Fluorescence and Photothermal Radiometry and Modulated Luminescence Methods

2015· article· en· W1715989194 on OpenAlexaboutno aff
Mahmoud Jallad, Domenick T. Zero, George J. Eckert, Andréa Ferreira Zandoná

Bibliographic record

VenueCaries Research · 2015
Typearticle
Languageen
FieldDentistry
TopicDental Health and Care Utilization
Canadian institutionsnot available
Fundersnot available
KeywordsRepeatabilityDentistryIntraclass correlationReceiver operating characteristicPermanent teethMedicineReproducibilityOrthodonticsChemistry

Abstract

fetched live from OpenAlex

BACKGROUND: The paradigm shift towards the nonsurgical management of dental caries relies on the early detection of the disease. Detection of caries at an early stage is of unequivocal importance for early preventive intervention. OBJECTIVE: The aim of this in vitro study is to evaluate the performance of a visual examination using the International Caries Detection and Assessment System (ICDAS) criteria, two quantitative light-induced fluorescence (QLF) systems--Inspektor™ Pro and QLF-D Biluminator™ 2 (Inspektor Research Systems B.V., Amsterdam, The Netherlands)--and a photothermal radiometry and modulated luminescence, The Canary System® (Quantum Dental Technologies, Toronto, Ont., Canada) on the detection of primary occlusal caries on permanent teeth. METHODS: A total of 60 teeth with occlusal surface sites ranging from sound to noncavitated lesions (ICDAS 0-4) were assessed with each detection method twice in a random order. Histological validation was used to compare methods for sensitivity, specificity, percent correct, and the area under the receiver operating characteristic curve (AUC), at standard and optimum sound thresholds. Interexaminer agreement and intraexaminer repeatability were measured using intraclass correlation coefficients. RESULTS: Interexaminer agreement ranged between 0.48 (The Canary System®) and 0.96 (QLF-D Biluminator™ 2). Intraexaminer repeatability ranges were 0.33-0.63 (The Canary System®) and 0.96-0.99 (QLF-D Biluminator™ 2). The sensitivity range was 0.75-0.96 while that of specificity was 0.43-0.89. The AUC were 0.79 (The Canary System®), 0.87 (ICDAS), 0.90 (Inspektor™ Pro), and 0.94 (QLF-D Biluminator™ 2). CONCLUSION: ICDAS had the best combination of sensitivity and specificity followed by QLF-D Biluminator™ 2 at optimum threshold.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.438
Teacher spread0.373 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueCaries ResearchSame topicDental Health and Care UtilizationFrench-language works237,207