MétaCan
Menu
Back to cohort

Hemodynamic responses to a hemoglobin bis‐tetramer and its polyethylene glycol conjugate

2011· article· en· W1759000000 on OpenAlexafffund
Francine E. Lui, Binglan Yu, David M. Baron, Chong Lei, Warren M. Zapol, Ronald Kluger

Bibliographic record

VenueTransfusion · 2011
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicHemoglobin structure and function
Canadian institutionsToronto General HospitalUniversity of Toronto
FundersCanadian Institutes of Health ResearchMassachusetts General Hospital
KeywordsHemoglobinBlood substituteNitric oxidePolyethylene glycolPEG ratioChemistryNitriteVasodilationVascular resistanceHemodynamicsIn vivoPharmacologyDeoxygenated HemoglobinMedicineBiochemistryInternal medicineBiology

Abstract

fetched live from OpenAlex

BACKGROUND: The design of hemoglobin-based oxygen carriers (HBOCs) poses a significant challenge as clinical trials of many materials have reported adverse side effects that may come from the scavenging of the vasodilator nitric oxide (NO). A compensating reaction, reduction of endogenous nitrite by hemoglobin (Hb) and its derivatives, generates NO. Polyethylene glycol (PEG) conjugation of Hb enhances the rate of the reaction. STUDY DESIGN AND METHODS: Hemoglobin bis-tetramers (BT) and their PEGylated derivative (BT-PEG) bind oxygen with a degree of cooperativity and also have significantly enhanced nitrite reductase activity compared to the native protein. Circulatory evaluation will test if the properties of BT and BT-PEG are reflected in their effects in vivo. BT and BT-PEG were evaluated as infusions into healthy wild-type (WT) and diabetic (db/db) mouse models. The effects were compared to infusions of murine Hb. RESULTS: The materials were found not to cause significant increases in systemic blood pressure in either WT mice or db/db mice. The latter are highly sensitive to NO scavenging. Further hemodynamic measurements in WT mice indicate that while a slight increase in systemic vascular resistance (SVR) was observed after infusion of BT, the extent is not significant. No change in SVR from baseline was observed after infusion of BT-PEG. CONCLUSION: The enlarged Hb derivatives do not evoke unfavorable circulatory responses that have been noted to result from infusion of Hb derivatives. These results suggest that a compromise between the P(50) , n(50) , and nitrite reductase activity of a Hb derivative can serve as the basis for producing HBOCs that can be tested for vasoactivity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.238
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueTransfusionSame topicHemoglobin structure and functionFrench-language works237,207