MétaCan
Menu
Back to cohort
Record W1781755474

Optimisation of fixation methods For Vancouver Type B2 And B3 periprosthetic femoral fracture treatment

2014· dissertation· en· W1781755474 on OpenAlexaboutno aff
Lee W. Etchels

Bibliographic record

VenueWhite Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · 2014
Typedissertation
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
FundersWellcome TrustNational Institute for Health and Care ResearchStrykerEngineering and Physical Sciences Research CouncilBritish Orthopaedic Association
KeywordsPeriprostheticFemoral fractureMedicineFemurOsteoporosisOrthodonticsArthroplastyFixation (population genetics)ProsthesisSurgeryBiomechanicsPopulationInternal medicineAnatomy
DOInot available

Abstract

fetched live from OpenAlex

Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected to occur more frequently in the future. The most common type of PFF is the Vancouver Type B fracture that occurs near the tip of the original prosthesis. These fractures can be complicated further by loosening of the primary femoral stem (Type B2 fractures) and poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. \nThis study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF at a range of loading orientations to evaluate their biomechanical response. From these specimens the axial stiffness, medial axial strain, distal lateral axial strain, and relative fracture movement were recorded under semi-physiological loading. These experimental results were also used to validate computational, finite element (FE), models of long stem PFF treatment. The computational models were shown to achieve reasonable agreement with the experimental data, such that they could be used to investigate a wider range of clinical scenarios. The FE models were then used to compare the relative effects of different cement mantle geometries, fracture location, fracture bridging distance, fracture angle, revision femoral stem length and osteoporosis. \nThe specific location and angle of the fracture appeared to have an effect on the bending response of the femur and the optimal treatment. Long stem revision treatment however seemed to be suitable for achieving stability around an unstable fracture and it may be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance. \n

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.272
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueWhite Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)Same topicOrthopaedic implants and arthroplastyFrench-language works237,207